To read this content please select one of the options below:

Shear-bearing capacity analysis under static force for shear key of the reinforced concrete open-web sandwich slab applied to long-span structure

Yu hui Fan (Space Structures Research Center, Guizhou University, Guiyang, China)
Pan pan Liu (Space Structures Research Center, Guizhou University, Guiyang, China)
Bo Shen (Space Structures Research Center, Guizhou University, Guiyang, China)
Kejian Ma (Space Structures Research Center, Guizhou University, Guiyang, China)
Bang Wu (School of Civil Engineering, Hunan University, Changsha, China)
Tianhong Zheng (Space Structures Research Center, Guizhou University, Guiyang, China)
Fang Yang (Space Structures Research Center, Guizhou University, Guiyang, China)

International Journal of Structural Integrity

ISSN: 1757-9864

Article publication date: 27 March 2020

Issue publication date: 13 April 2021

188

Abstract

Purpose

The reinforced concrete open-web sandwich slab is composed of upper rib, lower rib, surface plate and shear key and was applied to long-span structure crossing at 18–30 m. The shear-bearing capacity of shear key, having vital effects on the slab’s bearing capacity, is analysed to present its calculation formula used for the engineering application of the slab.

Design/methodology/approach

The shear-bearing capacity of shear key is analysed by the strut-and-tie model and the benchmark model established by the finite element method. Furthermore, the design formula of its shear capacity is given by the parametric analysis of FEM to adjust the result of the strut-and-tie model, using multivariate linear regression analysis of these parameters.

Findings

The calculation result of the benchmark model is compared with those of the strut-and-tie model and the standard formula, which indicates that the result of the strut-and-tie model is closer to that of the benchmark model than that of the standard formula. Moreover, the parametric analysis of the finite element model indicates that the volume–stirrup ratio of the shear key and the compression strength of the concrete have lesser effect on the shear capacity compared with the longitudinal reinforcement ratio and the shear-to-span ratio of the shear key and the relative section height of the rib.

Originality/value

The shear capacity of the shear key is provided in the paper by combining the finite element method and the strut-and-tie model, which is different from the calculation of the shear key in local codes and Chinese code, based on the theory of short corbel and the experiment of member. Furthermore, the formula of the shear capacity could be employed in the design and construction of the RC open-web sandwich slab, mainly used in the public and industrial multi-story building with long span to save the dwindling land resource currently.

Keywords

Acknowledgements

The work described in this paper was fully supported by three grants from the First Class Subject Foundation of Civil Engineering of Guizhou Province under contract no. QYNYL[2017] 0013, the Natural Science Research Project of Guizhou Province Department of Education under contract no. [2015] 364 and the Science and Technology Support Plan Project (Social Development Breakthrough) of Guizhou Province under contract no. Qian Ke He SY [2012] 3067.

Citation

Fan, Y.h., Liu, P.p., Shen, B., Ma, K., Wu, B., Zheng, T. and Yang, F. (2021), "Shear-bearing capacity analysis under static force for shear key of the reinforced concrete open-web sandwich slab applied to long-span structure", International Journal of Structural Integrity, Vol. 12 No. 2, pp. 195-213. https://doi.org/10.1108/IJSI-11-2019-0121

Publisher

:

Emerald Publishing Limited

Copyright © 2019, Emerald Publishing Limited