1 – 2 of 2Yan Yin, Heng Zhou, Jiusheng Bao, Zengsong Li, Xingming Xiao and Shaodi Zhao
This paper aims to overcome the defect of single-source temperature measurement method and improve the measurement accuracy of FTR. The friction temperature rise (FTR) of brake…
Abstract
Purpose
This paper aims to overcome the defect of single-source temperature measurement method and improve the measurement accuracy of FTR. The friction temperature rise (FTR) of brake affects braking performance seriously. However, it was mainly detected by single-source indirect thermometry, which has obvious deviations.
Design/methodology/approach
A three-point temperature measurement system was built based on three kinds of single-resource thermometry. Temperature characteristics of these thermometry were analyzed to achieve a standard FTR curve. Two fusion-monitoring models for FTR based on multi-source information were established by artificial neural network (ANN) and support vector machine (SVM).
Findings
Finally, the two models were verified based on the experimental results. The results showed that the fusion-monitoring model of SVM was more accurate than that of ANN in monitoring of FTR.
Originality/value
Then the temperature characteristics of the three single-source thermometry were analyzed, and the fusion-monitoring models based on multi-source information were established by ANN and SVM. Finally, the accuracy of the two models was compared by the experimental results. The more suitable fusion-monitoring model for FTR monitoring was determined which would be of theoretical and practical significance for remedying the monitoring defect of FTR.
Details
Keywords
Shaodi Zhao, Yan Yin, Jiusheng Bao, Xingming Xiao, Zengsong Li and Guoan Chen
The friction between brake pair causes an intense temperature rise on interface during braking, which affects the braking performance seriously. Therefore, building an accurate…
Abstract
Purpose
The friction between brake pair causes an intense temperature rise on interface during braking, which affects the braking performance seriously. Therefore, building an accurate testing method for frictional temperature rise (FTR) is a prerequisite.
Design/methodology/approach
Facing braking conditions of automobiles, an experimental system for testing of FTR based on preset thermometry method (PTM) was established. The FTR was collected by the PTM and the variation laws as well as the cause of errors were analyzed by experiments. The deviations between tested and real temperature were corrected based on tribology and heat theories. Finally, an online prediction method for FTR was pointed out.
Findings
After correction, the temperature curve accords well with the laws of tribology and thermal theories. The corrected FTR at braking end point is approximately equal to the authentic temperature test by hand thermometer.
Originality/value
This study eliminated the hysteresis phenomenon of temperature rise sequence and lays a foundation for online accurate monitoring and warning of brake friction temperature rise. It has important theoretical and practical value for expanding the monitoring and improvement of brake performance.
Details