Wei Yang, Linghui Xu, Linfan Yu, Yuting Chen, Zehao Yan and Canjun Yang
Walking-aid exoskeletons can assist and protect effectively the group with lower limb muscle strength decline, workers, first responders and military personnel. However, there is…
Abstract
Purpose
Walking-aid exoskeletons can assist and protect effectively the group with lower limb muscle strength decline, workers, first responders and military personnel. However, there is almost no united control strategy that can effectively assist daily walking. This paper aims to propose a hybrid oscillators’ (HOs) model to adapt to irregular gait (IG) patterns (frequent alternation between walking and standing or rapid changing of walking speed, etc.) and generate compliant and no-delay assistive torque.
Design/methodology/approach
The proposed algorithm, HOs, combines adaptive oscillators (AOs) with phase oscillator through switching assistive mode depending on whether or not the AOs' predicting error of hip joint degree is exceeded our expectation. HOs can compensate for delay by predicting gait phase when in AOs mode. Several treadmill and free walking experiments are designed to test the adaptability and effectiveness of HOs model under IG.
Findings
The experimental results show that the assistive strategy based on the HOs is effective under IG patterns, and delay is compensated totally under quasiperiodic gait conditions where a smoother human–robot interaction (HRI) force and the reduction of HRI force peak are observed. Delay compensation is found very effective at improving the performance of the assistive exoskeleton.
Originality/value
A novel algorithm is proposed to improve the adaptability of a walking assist hip exoskeleton in daily walking as well as generate compliant, no-delay assistive torque when converging.
Details
Keywords
This paper aims to propose a soft actuator that combines a sponge-based actuating structure and a layer-jamming-based stiffness-improving structure in a cavity.
Abstract
Purpose
This paper aims to propose a soft actuator that combines a sponge-based actuating structure and a layer-jamming-based stiffness-improving structure in a cavity.
Design/methodology/approach
The proposed soft actuator consists of film-constrained sponge units (FCSUs) and jamming layers. The FCSUs in the proposed soft actuator bend under vacuum pressure, causing bending deformation of the entire actuator. The jamming layers are strongly coupled through friction under vacuum pressure, increasing the stiffness of the entire actuator. The performance of the proposed soft actuator was examined by measuring its stiffness, bending deformation and response performance. A four-finger soft robotic gripper was proposed based on the proposed soft actuator.
Findings
Through experiments, it was shown that the proposed soft actuator exhibited acceptable bending deformation, stiffness and response. Moreover, the proposed four-finger soft gripper could effectively grasp objects in daily life.
Originality/value
In this study, the authors proposed a novel bending actuator (with a volume of approximately 43.2 cm3) based on FCSUs and jamming layers. To the best of the authors’ knowledge, this is the first study to combine a sponge-based actuating structure and a layer-jamming structure in a cavity to achieve simultaneous change in actuation and stiffness. The soft actuator exhibited good bending deformation and high stiffness simultaneously under vacuum pressure. Consequently, it could be used effectively to fabricate soft grippers.