Mohd Rashid, Umesh S. Waware, Afidah A. Rahim and A.M.S. Hamouda
The purpose of this study is to compare the inhibitive effect of polyaniline (PAni) and N-cetyl-N,N,N trimethyl ammonium bromide (CTAB)-stabilized PAni in a hydrochloric acid…
Abstract
Purpose
The purpose of this study is to compare the inhibitive effect of polyaniline (PAni) and N-cetyl-N,N,N trimethyl ammonium bromide (CTAB)-stabilized PAni in a hydrochloric acid (HCl) medium.
Design/methodology/approach
PAni has been deposited potentiodynamically on mild steel in the presence of CTAB as a stabilizing agent to achieve high corrosion inhibition performance by the polymer deposition. The corrosion inhibition studies of CTAB-stabilized PAni inhibitor in 0.1 M HCl acidic solution was carried out by electrochemical methods, namely, open-circuit potential, potentiodynamic polarization and electrochemical impedance spectroscopy technique.
Findings
The results of electrochemical studies have shown that the CTAB-stabilized PAni inhibitor has higher corrosion efficiency than PAni on mild steel in 0.1 M HCl solution. The maximum per cent efficiency evaluated using the potentiodynamic polarization method is approximately 91.9.
Originality/value
CTAB-stabilized PAni has never been studied as a corrosion inhibitor for mild steel in an acidic medium. The investigations demonstrate relatively the better corrosion inhibition efficiency and high dispersion of the polymer in the acidic medium.
Details
Keywords
Mohd Rashid, Suhail Sabir, Umesh Waware and Afidah A. Rahim
– This paper aims to compare the inhibitive effects of polyaniline (PAni), poly(p-toluidine) and poly(aniline-co-p-toluidine) in hydrochloric acid (HCl) solution.
Abstract
Purpose
This paper aims to compare the inhibitive effects of polyaniline (PAni), poly(p-toluidine) and poly(aniline-co-p-toluidine) in hydrochloric acid (HCl) solution.
Design/methodology/approach
The electrochemical deposition of PAni, poly(p-toluidine) and poly(aniline-co-p-toluidine) on pure copper metal was studied potentiodynamically. The copolymer deposited was characterized by Fourier transform infrared (FTIR) spectroscopy, ultraviolet (UV)-visible spectroscopy and scanning electron microscopy (SEM). The corrosion inhibition studies on copper electrode were performed using electrochemical methods, viz, open circuit potential (OCP) measurements, potentiodynamic polarization scans and electrochemical impedance spectroscopy (EIS) tests, conducted in 0.1 M HCl solution.
Finding
The results of the study reveal that the copolymer of poly(aniline-co-p-toluidine) at the optimum concentration of 1 × 10−3 M has better corrosion inhibition efficiency as compared to PAni and poly(p-toluidine).
Research limitations/implications
The conducting polymers are difficult to deposit on the metal surface because of their high dissolution tendency before the electropolymerization potential of the monomer is achieved.
Practical implications
From an environmental viewpoint, poly(aniline-co-p-toluidine) is a toxic and hazardous conducting polymer.
Originality/value
The paper demonstrates that poly(aniline-co-p-toluidine) showed better dispersion in different organic solvents and had higher corrosion inhibition efficiency than PAni.