Search results
1 – 3 of 3Hui-Feng Wang, Gui-ping Wang, Xiao-Yan Wang, Chi Ruan and Shi-qin Chen
This study aims to consider active vision in low-visibility environments to reveal the factors of optical properties which affect visibility and to explore a method of obtaining…
Abstract
Purpose
This study aims to consider active vision in low-visibility environments to reveal the factors of optical properties which affect visibility and to explore a method of obtaining different depths of fields by multimode imaging.Bad weather affects the driver’s visual range tremendously and thus has a serious impact on transport safety.
Design/methodology/approach
A new mechanism and a core algorithm for obtaining an excellent large field-depth image which can be used to aid safe driving is designed and implemented. In this mechanism, atmospheric extinction principle and field expansion system are researched as the basis, followed by image registration and fusion algorithm for the Infrared Extended Depth of Field (IR-EDOF) sensor.
Findings
The experimental results show that the idea we propose can work well to expand the field depth in a low-visibility road environment as a new aided safety-driving sensor.
Originality/value
The paper presents a new kind of active optical extension, as well as enhanced driving aids, which is an effective solution to the problem of weakening of visual ability. It is a practical engineering sensor scheme for safety driving in low-visibility road environments.
Details
Keywords
Jian Feng Li, Qin Shi, HeJun Zhu, ChenYu Huang, Shuai Zhang, Weixiang Peng and ChangSheng Li
This paper aims to clarify the size and morphology of transition metal dichalcogenides has an impact on lubrication performance of Cu-based composites. This study is intended to…
Abstract
Purpose
This paper aims to clarify the size and morphology of transition metal dichalcogenides has an impact on lubrication performance of Cu-based composites. This study is intended to show that Cu-based electrical contact materials containing Nb0.91Ti0.09Se2 have better electrical and tribological properties than those containing NbSe2. The tribological properties of Cu-based with different Ti-dopped NbSe2 content were also discussed.
Design/methodology/approach
The NbSe2 and Nb0.91Ti0.09Se2 particles were fabricated by thermal solid state reaction method. The powder metallurgy technique was used to fabricate composites with varying Nb0.91Ti0.09Se2 mass fraction. The phase composition of Cu-based composites was identified by X-ray diffraction, and the morphology of NbSe2/Nb0.91Ti0.09Se2 and the worn surface of composites were characterized by scanning electron microscopy and transmission electron microscopy. In addition, the tribological properties of composites were appraised using a ball-on-disk multi-functional tribometer. The data of friction coefficient and resistivity were analyzed and the corresponding conclusion was drawn.
Findings
In comparison with the pure copper, Cu-based composites containing Nb0.91Ti0.09Se2/NbSe2 had a lower friction coefficient, illustrating the Nb0.91Ti0.09Se2 with nano-size particles prepared in this work is a perfect choice for the fabrication of excellent electrical contact composites. Compared to composites with NbSe2, composites containing Nb0.91Ti0.09Se2 have better tribological and electrical properties.
Research limitations/implications
Because of the use of thermal solid state reaction method, the size of NbSe2 and Nb0.91Ti0.09Se2 is relatively large. Therefore, the fabrication of finer particles of Nb0.91Ti0.09Se2 is encouraged.
Originality/value
In this paper, the authors discuss the tribological and electrical properties of Cu-based composites, and the value of optimum obtained as Nb0.91Ti0.09Se2 content is 15 Wt.%.
Details
Keywords
Hui Pan, Na Li Wang and Yin Shi Qin
The purpose of this paper is to propose a method that calibrates the hand-eye relationship for eye-to-hand configuration and afterwards a rectification to improve the accuracy of…
Abstract
Purpose
The purpose of this paper is to propose a method that calibrates the hand-eye relationship for eye-to-hand configuration and afterwards a rectification to improve the accuracy of general calibration.
Design/methodology/approach
The hand-eye calibration of eye-to-hand configuration is summarized as a equation AX = XB which is the same as in eye-in-hand calibration. A closed-form solution is derived. To abate the impact of noise, a rectification is conducted after the general calibration.
Findings
Simulation and actual experiments confirm that the accuracy of calibration is obviously improved.
Originality/value
Only a calibration plane is required for the hand-eye calibration. Taking the impact of noise into account, a rectification is carried out after the general calibration and, as a result, that the accuracy is obviously improved. The method can be applied in many actual applications.
Details