Search results
1 – 2 of 2Zhu Feng, Shaotao Zhi, Lei Guo, Chong Lei and Yong Zhou
This paper aims to investigate magnetic field anneal in micro-patterned Co-based amorphous ribbon on giant magneto-impedance (GMI) effect enhancement.
Abstract
Purpose
This paper aims to investigate magnetic field anneal in micro-patterned Co-based amorphous ribbon on giant magneto-impedance (GMI) effect enhancement.
Design/methodology/approach
The amorphous ribbons were annealed in transverse and longitudinal magnetic field. The influence of different field annealing directions on GMI effect and impedance Z, resistance R and reactance X with a series of line width have been deeply analyzed.
Findings
In comparison with GMI sensors microfabricated by unannealed and transversal field annealed ribbons, GMI sensor which was designed and microfabricated by longitudinal field anneal ribbon performs better. The results can be explained by the domain wall motion and domain rotation during annealing process and the geometric structure of Co-based GMI sensor. In addition, shrinking the line width of GMI sensor can promote GMI effect significantly because of the effect of demagnetizing field, and the optimum GMI ratio is 209.7 per cent in longitudinal field annealed GMI sensor with 200 μm line width.
Originality/value
In conclusion, annealing in longitudinal magnetic field and decreasing line width can enhance GMI effect in micro-patterned Co-based amorphous ribbon.
Details
Keywords
Zhu Feng, Shaotao Zhi, Xuecheng Sun, Lili Yan, Cui Liu and Chong Lei
This paper aims to investigate the influence of structure parameters on giant-magnetoimpedance (GMI) effect measured by non-contact method.
Abstract
Purpose
This paper aims to investigate the influence of structure parameters on giant-magnetoimpedance (GMI) effect measured by non-contact method.
Design/methodology/approach
The GMI sensor contains a Co-based internal magnetic core fabricated by laser cutting and an external solenoid. The influences of magnetic permeability of magnetic core and structure parameters on GMI effect were calculated in theoretical model. The output impedance, resistance, reactance and GMI ratio were measured by non-contact method using impedance analyzer.
Findings
Enhancing external magnetic field intensity can decrease the magnetic permeability of core, which has vital influences on the magnetic property and the output response of GMI sensor. In addition, increasing the width of magnetic core and the number of solenoid turns can increase the maximum GMI ratio. The maximum GMI ratio is 3,230% with core width of 6 mm and solenoid turns of 200.
Originality/value
Comparing with traditional contact-measured GMI sensor, the maximum GMI ratio and the magnetic field sensitivity are improved and the power consumption is decreased in non-contact measured GMI sensor. GMI sensor measured by non-contact method has a wide range of potential applications in ultra-sensitive magnetic field detection.
Details