Sara Stingl de Freitas and Vasco Peixoto de Freitas
The purpose of this paper is to present a case study of cracks on external thermal insulation composite systems (ETICS) along the thermal insulation joints and the information…
Abstract
Purpose
The purpose of this paper is to present a case study of cracks on external thermal insulation composite systems (ETICS) along the thermal insulation joints and the information available on the building pathology catalogue – PATORREB. The aim is to establish the methodology to study the cause of the pathology observed on a building which is located on the interior of Portugal based on in situ probing together with the analysis of hygrothermal and mechanical behaviour.
Design/methodology/approach
An in situ analysis was performed to assess the causes. The hygrothermal dynamic behaviour of the wall was analysed with a numerical simulation advanced tool considering the climatic conditions, the characteristics of the thermal insulation plates as well as the support and finishing layer properties. Moreover, a qualitatively analysis of the mechanical behaviour, based on the bonding process, thermal insulation and exterior rendering properties was performed.
Findings
It was concluded that the insulation properties – thermal expansion coefficient and stiffness, the thermal expansion coefficient of the exterior rendering, together with adverse climatic conditions were critical for the appearance of cracks along the plate joints, particularly with spot bonding. The expansion and retraction stresses and the restrained movements of the components can result in bending moments, especially when the insulation material has a high stiffness value, which will create the crack on the rendering system.
Originality/value
A combination between a hygrothermal and mechanical analysis of an ETICS pathology concerning the appearance of cracks with a subsequent integration into a building pathology catalogue.
Details
Keywords
Elton Bauer, Vasco Peixoto de Freitas, Niubis Mustelier, Eva Barreira and Sara Stingl de Freitas
Infrared thermography is increasingly being used to diagnose pathologies in buildings, such as façade defects. The purpose of this paper is to assess the results reproducibility…
Abstract
Purpose
Infrared thermography is increasingly being used to diagnose pathologies in buildings, such as façade defects. The purpose of this paper is to assess the results reproducibility and the equipment influence on the measurements. To do so, it was defined as case study the assessment of rendering delamination.
Design/methodology/approach
Two infrared cameras of different makers were used to detect the presence of defects deliberately created in specimens. The tests were done in the laboratory with a heat source. The defects were detected through a temperature gradient between the zones with and without defect.
Findings
With this thermographic imaging, it was possible to identify the defects in the specimen both qualitatively and quantitatively. The results were found to be reproducible in the three cycles performed. The influence of the equipment on the results was of little significance for the quantitative assessment criterion “temperature difference between zones with and without defect”, but for the criterion “absolute surface temperature”, the difference in the results yielded by the two cameras was around 1.8°C.
Originality/value
The results suggest that there is reproducibility of the measurements, considering both the qualitative and quantitative approach, when assessing delamination, irrespective of the maker of the equipment used. The influence of the equipment on the results depends on the quantitative assessment criterion used.