Diogo Henrique de Bem, Priscila Ongaratto Trentin and Ronaldo A. Medeiros-Junior
Efflorescence formation is very common in cement-based materials. In the case of mortar, efflorescence is more studied when only Portland cement is used as a binder. However, the…
Abstract
Purpose
Efflorescence formation is very common in cement-based materials. In the case of mortar, efflorescence is more studied when only Portland cement is used as a binder. However, the repair of historical heritage, as well as the construction system of some countries, usually uses mortars composed of hydrated lime and Portland cement. This study aims to determine the influence of the hydrated lime content on the incidence of efflorescence in mortars.
Design/methodology/approach
Mortars with 0%, 50%, and 100% lime/cement ratio were studied, using three different methods to accelerate efflorescence formation. The surface area of mortars affected by efflorescence was quantified by analysis using image software. Also, analysis of mercury intrusion porosity test, flexural tensile, compressive strength, absorption of water by capillarity, porosity, XRD and TGA was performed.
Findings
More efflorescence in mortars with a higher amount of lime in their composition was observed. The results show that the increase in the lime content reduces the flexural tensile and the compressive strength and increased the absorption of water by capillarity and the porosity of the mortars. The material formed by the efflorescence was calcium carbonate, proven by microstructural tests.
Originality/value
The results of greater efflorescence formation in mortars with lime are important to alert users who apply this type of material. Some type of protection must be done more rigorously for lime-cement mortars, especially concerning contact with water, since efflorescence tends to be faster for this type of material.
Details
Keywords
Diogo Henrique de Bem, Daniel Petzold Barbosa Lima and Ronaldo A. Medeiros-Junior
The purpose of this paper is to verify the influence of superplasticizer and air entrainment admixtures (AEs) in the electrical resistivity of concrete.
Abstract
Purpose
The purpose of this paper is to verify the influence of superplasticizer and air entrainment admixtures (AEs) in the electrical resistivity of concrete.
Design/methodology/approach
Ten different types of concrete have been studied. Three levels of superplasticizer and air AEs have been used (0.20, 0.35 and 0.50 per cent). Concrete samples were cast and the electrical resistivity was monitored at the ages of 28, 63 and 91 days. Compressive strength and density tests have also been executed.
Findings
The superplasticizer admixture presented an optimal level of 0.35 per cent that significantly increased the electrical resistivity. The air AEs at the same dosage caused a considerable decrease in the electrical resistivity. The concrete with air AEs showed highest resistivity/MPa ratio.
Research limitations/implications
The results should be carefully extrapolated for other materials and admixtures.
Practical implications
The usage of chemicals admixture in concrete is extremely common nowadays. However, only a few authors have studied the impact of such materials on the concrete’s electrical resistivity. Since many other researchers have already correlated electrical resistivity with other concrete’s properties, such as strength, setting time and corrosion probability, it is important to better understand how superplasticizers and air-entraining agents, for instance, impact the resistivity.
Originality/value
The vast majority of studies only tested the resistivity of cement paste or mortar and usually for short period of time (up to 28 days), which seems not to be adequate since the cement reaction continues after that period. This paper fills this gap and studied the impact of admixture on concrete and for a period of 91 days.
Details
Keywords
Ian C.A. Esteves, Ronaldo A. Medeiros-Junior and Marcelo H.F. Medeiros
The limitation of bridges’ operation can cause serious social, environmental and economic losses. Therefore, the monitoring and maintenance actions of these structures must be…
Abstract
Purpose
The limitation of bridges’ operation can cause serious social, environmental and economic losses. Therefore, the monitoring and maintenance actions of these structures must be efficient and periodic, especially for bridges located in aggressive environments, such as urban-industrial centres, where the higher volume of carbon dioxide emissions favours carbonation induced corrosion. The purpose of this paper is to analyse the utility of including non-destructive testing (NDTs) to bridges assessment in that regions as a way of obtaining more in-depth information on the conditions of the material composing the structure.
Design/methodology/approach
First, the main bridges’ damages were detected by visual inspection. Then, based on the observations of bridges design, environment and main damages, an NDT programme was executed including surface hardness, ultrasonic pulse velocity test, pH indicator spraying, half-cell potential measurements and concrete resistivity tests.
Findings
It was observed that, for the studied cases, the carbonation did not present harmful depths, except for the structural elements where segregation and wear of the concrete were noticed. NDTs, associated with visual inspection, indicated the regions where corrective or preventive maintenance actions were actually needed, bringing greater security to the decision maker in regions where repairs are unnecessary or could be postponed.
Originality/value
This paper highlights the contribution of NDTs application in structures in urban-industrial regions where the main mechanism of deterioration is carbonation-induced corrosion, demonstrating the importance of these methods in the rational decision making of investments for maintenance.