Mahdi Valitabar, Mohammadjavad Mahdavinejad, Henry Skates and Peiman Pilechiha
The aim of this paper is to present a parametric design method to generate optimum adaptive facades regarding occupants' comfort and building energy criteria. According to the…
Abstract
Purpose
The aim of this paper is to present a parametric design method to generate optimum adaptive facades regarding occupants' comfort and building energy criteria. According to the literature review, the following questions have arisen to address the research gaps: Is it possible to have the outside view throughout the whole year without discomfort glare by utilising adaptive solar facades (ASFs)? How can architects integrate both view quality and quantity into ASF design? What is the impact of dynamic vertical shading systems mounted on south facades on the outside view, occupants' visual comfort and operational energy? How can we evaluate the view quantity through multi-layer shading systems?
Design/methodology/approach
In recent years, there is a surge in demand for fully glazed buildings, motivating both architects and scholars to explore novel ideas for designing adaptive solar facades. Nevertheless, the view performance of such systems has not been fully explored especially when it comes to the effect of dynamic vertical shading systems mounted on south facades. This fact clarifies the need to conduct more research in this field by taking into account the window view and natural light. Consequently, a simulation research is carried out to investigate the impact of a dynamic shading system with three vertical slats used on the south facade of a single office room located in Tehran, on both view quality and quantity, visual comfort and operational energy. The research attempts to reach a balance between the occupant's requirements and building energy criteria through a multi-objective optimisation. The distinctive feature of the proposed method is generating some optimum shading which could only cover the essential parts of the window area. It was detected from the simulation results that the usage of a dynamic vertical shading system with multi slats for south facades compared to common Venetian blinds can firstly, provide four times more view quantity. Secondly, the view quality is significantly improved through enabling occupants to enjoy the sky layer the entire year. Finally, twice more operational energy can be saved while more natural light can enter the indoor environment without glare. The final outcome of this research contributes toward designing high-performance adaptive solar facades.
Findings
This paper proposes a new metric to evaluate the view quantity through a multi-layer shading system. The proposed method makes it clear that the usage of dynamic vertical shading systems with multi-layers mounted on south facades can bring many benefits to both occupants and building energy criteria. The proposed method could (1) provide four times more view quantity; (2) improve view quality by enabling occupants to watch the sky layer throughout the whole year; (3) slash the operational energy by twice; (4) keep the daylight glare probability (DGP) value in the imperceptible range.
Research limitations/implications
The research limitations that should be acknowledged are ignoring the impact of the adjacent building on sunlight reflection, which could cause discomfort glare issues. Another point regarding the limitations of the proposed optimisation method is the impact of vertical shading systems on users' visual interests. A field study ought to be conducted to determine which one could provide the more desirable outside view: a vertical or horizontal the view. Research on the view performance of ASFs, especially their impact on the quality of view, is sorely lacking.
Originality/value
This paper (1) analyses the performance of dynamic vertical shadings on south facades; (2) evaluates outside view through multi-layer shading systems; and (3) integrates both view quality and quantity into designing adaptive solar facades.
Details
Keywords
Peiman Pilechiha, Alireza Norouziasas, Hoorieh Ghorbani Naeini and Kasmir Jolma
In vernacular buildings, many climatic and passive solutions have been used to create indoor thermal comfort. Seasonal occupant movement is an example of a traditional response to…
Abstract
Purpose
In vernacular buildings, many climatic and passive solutions have been used to create indoor thermal comfort. Seasonal occupant movement is an example of a traditional response to increasing thermal comfort. This article investigates the influence of these user behaviours on thermal comfort in courtyard houses.
Design/methodology/approach
Parametric models of three different scenarios of courtyard houses are simulated. The courtyard houses are located in Shiraz, Iran, and share the same orientation and construction materials. To enhance the accuracy of the study, the indoor adaptive thermal comfort (ATC) analysis is performed with three different window-to-wall ratios (WWR) of 25, 50 and 75%. The ACT analysis is performed on an hourly basis for summer and winter scenarios.
Findings
The results demonstrate that the indoor ATC is 8.3% higher in winter than in the summer in the seasonal zones. During the summer, the amount of ATC is relatively sustained in all zones. Unlike common beliefs, seasonal movement can enhance the ATC, especially during winter, specifically in the northern part of the courtyard. In northern zones, the seasonal movement of occupants improves the indoor ATC from 10.1 to 23.7%, and in southern zones, the improvement is from 2.2 to 4.8%.
Originality/value
This research presents a new numerical investigation into occupants' seasonal movements in courtyard houses during summer and winter. It provides a precise pattern to show how much this seasonal movement can affect the habitant's ATC.