Thomas Gernay and Mohamed Salah Dimia
The paper aims to give an insight into the behaviour of reinforced concrete columns during and after the cooling phase of a fire. The study is based on numerical simulations as…
Abstract
Purpose
The paper aims to give an insight into the behaviour of reinforced concrete columns during and after the cooling phase of a fire. The study is based on numerical simulations as these tools are frequently used in structural engineering. As the reliability of numerical analysis largely depends on the validity of the constitutive models, the development of a concrete model suitable for natural fire analysis is addressed in the study.
Design/methodology/approach
The paper proposes theoretical considerations supported by numerical examples to discuss the capabilities and limitations of different classes of concrete models and eventually to develop a new concrete model that meets the requirements in case of natural fire analysis. Then, the study performs numerical simulations of concrete columns subjected to natural fire using the new concrete model. A parametric analysis allows for determining the main factors that affect the structural behaviour in cooling.
Findings
Failure of concrete columns during and after the cooling phase of a fire is a possible event. The most critical situations with respect to delayed failure arise for short fires and for columns with low slenderness or massive sections. The concrete model used in the simulations is of prime importance and the use of the Eurocode model would lead to unsafe results.
Practical implications
The paper includes implications for the assessment of the fire resistance of concrete elements in a performance‐based environment.
Originality/value
The paper provides original information about the risk of structural collapse during cooling.
Details
Keywords
Mahesh Gaikwad, Suvir Singh, N. Gopalakrishnan, Pradeep Bhargava and Ajay Chourasia
This study investigates the impact of the fire decay phase on structural damage using the sectional analysis method. The primary objective of this work is to forecast the…
Abstract
Purpose
This study investigates the impact of the fire decay phase on structural damage using the sectional analysis method. The primary objective of this work is to forecast the non-dimensional capacity parameters for the axial and flexural load-carrying capacity of reinforced concrete (RC) sections for heating and the subsequent post-heating phase (decay phase) of the fire.
Design/methodology/approach
The sectional analysis method is used to determine the moment and axial capacities. The findings of sectional analysis and heat transfer for the heating stage are initially validated, and the analysis subsequently proceeds to determine the load capacity during the fire’s heating and decay phases by appropriately incorporating non-dimensional sectional and material parameters. The numerical analysis includes four fire curves with different cooling rates and steel percentages.
Findings
The study’s findings indicate that the rate at which the cooling process occurs after undergoing heating substantially impacts the axial and flexural capacity. The maximum degradation in axial and flexural capacity occurred in the range of 15–20% for cooling rates of 3 °C/min and 5 °C/min as compared to the capacity obtained at 120 min of heating for all steel percentages. As the fire cooling rate reduced to 1 °C/min, the highest deterioration in axial and flexural capacity reached 48–50% and 42–46%, respectively, in the post-heating stage.
Research limitations/implications
The established non-dimensional parameters for axial and flexural capacity are limited to the analysed section in the study owing to the thermal profile, however, this can be modified depending on the section geometry and fire scenario.
Practical implications
The study primarily focusses on the degradation of axial and flexural capacity at various time intervals during the entire fire exposure, including heating and cooling. The findings obtained showed that following the completion of the fire’s heating phase, the structural capacity continued to decrease over the subsequent post-heating period. It is recommended that structural members' fire resistance designs encompass both the heating and cooling phases of a fire. Since the capacity degradation varies with fire duration, the conventional method is inadequate to design the load capacity for appropriate fire safety. Therefore, it is essential to adopt a performance-based approach while designing structural elements' capacity for the desired fire resistance rating. The proposed technique of using non-dimensional parameters will effectively support predicting the load capacity for required fire resistance.
Originality/value
The fire-resistant requirements for reinforced concrete structures are generally established based on standard fire exposure conditions, which account for the fire growth phase. However, it is important to note that concrete structures can experience internal damage over time during the decay phase of fires, which can be quantitatively determined using the proposed non-dimensional parameter approach.