Publication date: 14 March 2016

Mariusz Marcin Maslak and Marcin Lukacz

The purpose of this paper is to present and discuss in detail the design approach to shear buckling resistance evaluation for corrugated web being a part of a steel beam exposed…

78

Abstract

Purpose

The purpose of this paper is to present and discuss in detail the design approach to shear buckling resistance evaluation for corrugated web being a part of a steel beam exposed to fire.

Design/methodology/approach

It is based on the interaction between the local and global elastic instability failure modes as well as on the possible yielding of the whole web cross-section during fire.

Findings

New formulae, adequate for specification of the suitable shear buckling coefficients, depend not only on the web slenderness but also on the temperature of structural steel.

Originality/value

The methodology proposed by the authors can be added to the current European standard recommendations given in EN 1993-1-2 as a well-justified design algorithm helpful in reliable evaluation of a safety level for steel beams with slender corrugated webs subject to fire exposure. It seems to be highly desirable because, at present, there are no detailed instructions in this field.