Norihan Abdul Hamid, J. Yunas, B. Yeop Majlis, A.A. Hamzah and B. Bais

The purpose of this paper is to discuss the fabrication technology and test of thermo-pneumatic actuator utilizing Si3N4-polyimide thin film membrane. Thin film polyimide membrane…

Abstract

Purpose

The purpose of this paper is to discuss the fabrication technology and test of thermo-pneumatic actuator utilizing Si3N4-polyimide thin film membrane. Thin film polyimide membrane capped with Si3N4 thin layer is used as actuator membrane which is able to deform through thermal forces inside an isolated chamber. The fabricated membrane will be suitable for thermo-pneumatic-based membrane actuation for lab-on-chip application.

Design/methodology/approach

The actuator device consisting of a micro-heater, a Si-based micro-chamber and a heat-sensitive square-shaped membrane is fabricated using surface and bulk-micromachining process, with an additional adhesive bonding process. The polyimide membrane is capped with a thin silicon nitride layer that is fabricated by using etch stop technique and spin coating.

Findings

The deformation property of the membrane depend on the volumetric expansion of air particles in the heat chamber as a result of temperature increase generated from the micro-heater inside the chamber. Preliminary testing showed that the fabricated micro-heater has the capability to generate heat in the chamber with a temperature increase of 18.8 °C/min. Analysis on membrane deflection against temperature increase showed that heat-sensitive thin polyimide membrane can perform the deflection up to 65 μm for a temperature increase of 57°C.

Originality/value

The dual layer polyimide capped with Si3N4 was used as the membrane material. The nitride layer allowed the polyimide membrane for working at extreme heat condition. The process technique is simple implementing standard micro-electro-mechanical systems process.

Details

Microelectronics International, vol. 32 no. 1
Type: Research Article
ISSN: 1356-5362

Keywords

Article
Publication date: 5 May 2015

M.R. Buyong, J. Yunas, A.A. Hamzah, B. Yeop Majlis, F. Larki and N. Abd Aziz

The purpose of this study is to design and characterize the dielectrophoretic (DEP) microelectrodes with various array structure arrangements in order to produce optimum…

Abstract

Purpose

The purpose of this study is to design and characterize the dielectrophoretic (DEP) microelectrodes with various array structure arrangements in order to produce optimum non-uniform electric field for particle capture. The DEP-electrodes with 2D electrode structure was fabricated and characterized to see the effect of electrode structure configuration on the capture capability of the cells suspending in the solution.

Design/methodology/approach

The presented microelectrode array structures are made of planar conductive metal structure having same size and geometry. Dielectrophoretic force (FDEP) generated in the fluidic medium is initially simulated using COMSOL Multi-physics performed on two microelectrodes poles, which is then continued on three-pole microelectrodes. The proposed design is fabricated using standard MEMS fabrication process. Furthermore, the effect of different sinusoidal signals of 5, 10 and 15 volt peak to peak voltage (Vpp) at fixed frequency of 1.5 MHz on capturing efficiency of microelectrodes were also investigated using graphite metalloids particles as the suspended particles in the medium. The graphite particles that are captured at the microelectrode edges are characterized over a given time period.

Findings

Based on analysis, the capturing efficiency of microelectrodes at the microelectrode edges is increased as voltage input increases, confirming its dependency to the FDEP strength and direction of non-uniform electric field. This dependency to field consequently increases the surface area of the accumulated graphite. It is also showed that the minimum ratio of the surface accumulated area of captured graphite is 1, 2.75 and 9 μm2 for 5, 10 and 15 Vpp, respectively. The simulation result also indicates a significant improvement on the performance of microelectrodes by implementing third pole in the design. The third pole effect the particles in the medium by creating stronger non-uniform electric field as well as more selective force toward the microelectrodes’ edges.

Originality/value

The microelectrode array arrangement is found as a reliable method to increase the strength and selectivity of non-uniform electric field distribution that affect FDEP. The presented findings are verified through experimental test and simulation results.

Details

Microelectronics International, vol. 32 no. 2
Type: Research Article
ISSN: 1356-5362

Keywords

Open Access
Article
Publication date: 8 March 2022

Babarindé René Aderomou and McBride Nkhalamba

Establishing integrated reporting and thinking within mainstream business practice as the norm in the public and private sectors is fundamental. Corporate governance assessment in…

Abstract

Establishing integrated reporting and thinking within mainstream business practice as the norm in the public and private sectors is fundamental. Corporate governance assessment in the APRM Country Review Reports is not done in a way to enable more decision-useful reporting. This policy brief urges APRM's consultants to adopt a particular approach to frame corporate governance assessment. By adopting an inductive qualitative approach, retrieving academic articles and institutions' reports from the literature, this study develops a novel framework to ensure more reliability, completeness, consistency and comparability in the Country Review reporting. It is contended that such reporting can assist the APRM Country Review Missions in corporate governance assessment.

Details

Emerald Open Research, vol. 1 no. 13
Type: Research Article
ISSN: 2631-3952

Keywords

Article
Publication date: 4 September 2020

Muhamad Ramdzan Buyong, Farhad Larki, Celine Elie Caille, Norazreen Abd Aziz, Ahamad Ghadafi Ismail, Azrul Azlan Hamzah and Burhanuddin Yeop Majlis

This paper aims to present the dielectrophoresis (DEP) force (FDEP), defined as microelectrofluidics mechanism capabilities in performing selective detection and rapid…

Abstract

Purpose

This paper aims to present the dielectrophoresis (DEP) force (FDEP), defined as microelectrofluidics mechanism capabilities in performing selective detection and rapid manipulation of blood components such as red blood cells (RBC) and platelets. The purpose of this investigation is to understand FDEP correlation to the variation of dynamic dielectric properties of cells under an applied voltage bias.

Design/methodology/approach

In this paper, tapered design DEP microelectrodes are used and explained. To perform the characterization and optimization by analysing the DEP polarization factor, the change in dynamic dielectric properties of blood components are observed according to the crossover frequency (fxo) and adjustment frequency (fadj) variation for selective detection and rapid manipulation.

Findings

Experimental observation of dynamic dielectric properties change shows clear correlation to DEP polarization factor when performing selective detection and rapid manipulation. These tapered DEP microelectrodes demonstrate an in situ DEP patterning efficiency more than 95%.

Research limitations/implications

The capabilities of tapered DEP microelectrode devices are introduced in this paper. However, they are not yet mature in medical research studies for various purposes such as identifying cells and bio-molecules for detection, isolation and manipulation application. This is because of biological property variations that require further DEP characterization and optimization.

Practical implications

The introduction of microelectrofluidics using DEP microelectrodes operate by selective detecting and rapid manipulating via lateral and vertical forces. This can be implemented on precision health-care development for lab-on-a-chip application in microfluidic diagnostic and prognostic devices.

Originality/value

This study introduces a new concept to understand the dynamic dielectric properties change. This is useful for rapid, label free and precise methods to conduct selective detection and rapid manipulation of mixtures of RBC and platelets. Further, potential applications that can be considered are for protein, toxin, cancer cell and bacteria detections and manipulation. Implementation of tapered DEP microelectrodes can be used based on the understanding of dynamic dielectric properties of polarization factor analysis.

Details

Microelectronics International, vol. 37 no. 4
Type: Research Article
ISSN: 1356-5362

Keywords

Article
Publication date: 23 September 2020

Muhamad Ramdzan Buyong, Farhad Larki, Muhamad Ikhmal Hakimi Zainal, Abdelaziz Yousif Ahmed Almahi, Ahmad Ghadafi Ismail, Azrul Azlan Hamzah, Aminuddin Ahmad Kayani Kayani, Céline Elie Caille and Burhanuddin Yeop Majlis

This paper aims to present the capacitance characterization of tapered dielectrophoresis (DEP) microelectrodes as micro-electro-mechanical system sensor and actuator device. The…

Abstract

Purpose

This paper aims to present the capacitance characterization of tapered dielectrophoresis (DEP) microelectrodes as micro-electro-mechanical system sensor and actuator device. The application of DEP-on-a-chip (DOC) can be used to evaluate and correlate the capacitive sensing measurement at an actual position and end station of liquid suspended targeted particles by DEP force actuator manipulation.

Design/methodology/approach

The capability of both, sensing and manipulation was analysed based on capacitance changes corresponding to the particle positioning and stationing of the targeted particles at regions of interest. The mechanisms of DEP sensor and actuator, designed in DOC applications were energized by electric field of tapered DEP microelectrodes. The actual DEP forces behaviour has been also studied via quantitative analysis of capacitance measurement value and its correlation with qualitative analysis of positioning and stationing of targeted particles.

Findings

The significance of the present work is the ability of using tapered DEP microelectrodes in a closed mode system to simultaneously sense and vary the magnitude of manipulation.

Originality/value

The integration of DOC platform for contactless electrical-driven with selective detection and rapid manipulation can provide better efficiency in in situ selective biosensors or bio-detection and rapid bio-manipulation for DOC diagnostic and prognostic devices.

Details

Microelectronics International, vol. 37 no. 4
Type: Research Article
ISSN: 1356-5362

Keywords

Article
Publication date: 19 March 2019

Muhammad Izzuddin Abd Samad, Muhamad Ramdzan Buyong, Shyong Siow Kim and Burhanuddin Yeop Majlis

The purpose of this paper is to use a particle velocity measurement technique on a tapered microelectrode device via changes of an applied voltage, which is an enhancement of the…

Abstract

Purpose

The purpose of this paper is to use a particle velocity measurement technique on a tapered microelectrode device via changes of an applied voltage, which is an enhancement of the electric field density in influencing the dipole moment particles. Polystyrene microbeads (PM) have used to determine the responses of the dielectrophoresis (DEP) voltage based on the particle velocity technique.

Design/methodology/approach

Analytical modelling was used to simulate the particles’ polarization and their velocity based on the Clausius–Mossotti Factor (CMF) equation. The electric field intensity and DEP forces were simulated through the COMSOL numerical study of the variation of applied voltages such as 5 V p-p, 7 V p-p and 10 V p-p. Experimentally, the particle velocity on a tapered DEP response was quantified via the particle travelling distance over a time interval through a high-speed camera adapted to a high-precision non-contact depth measuring microscope.

Findings

The result of the particle velocity was found to increase, and the applied voltage has enhanced the particle trajectory on the tapered microelectrode, which confirmed its dependency on the electric field intensity at the top and bottom edges of the electrode. A higher magnitude of particle levitation was recorded with the highest particle velocity of 11.19 ± 4.43 µm/s at 1 MHz on 10 V p-p, compared to the lowest particle velocity with 0.62 ± 0.11 µm/s at 10 kHz on 7 V p-p.

Practical implications

This research can be applied for high throughout sensitivity and selectivity of particle manipulation in isolating and concentrating biological fluid for biomedical implications.

Originality/value

The comprehensive manipulation method based on the changes of the electrical potential of the tapered electrode was able to quantify the magnitude of the particle trajectory in accordance with the strong electric field density.

Details

Microelectronics International, vol. 36 no. 2
Type: Research Article
ISSN: 1356-5362

Keywords

Book part
Publication date: 24 October 2023

HyeSeung Lee

As the novel virus was declared a pandemic, Korean schools quickly transitioned to remote schooling based on its advanced IT system, government-operated digital learning…

Abstract

As the novel virus was declared a pandemic, Korean schools quickly transitioned to remote schooling based on its advanced IT system, government-operated digital learning platforms, and an abundance of pre-existing online teaching materials (Byun & Slavin, 2020). Unfortunately, this story of “successful” educational responses to the pandemic was of little relationship to physical education (PE) partly because of the sparsity of supportive resources for online teaching of the hands-on subject area but mainly because of the incompatibility between the nature of the online classroom and the essence of PE (Baek & Yoon, 2020; Oh, 2021). As its name implies, physical education is inseparable from physical movements, bodily dialogue, close physical contact, and active, direct interactions between engaged individuals. Accordingly, PE teachers, dwelling in either online or blended classrooms where bodies are absent, and touch is unthinkable, are experiencing diminished room to implement their pedagogical repertoires and, in turn, affecting their deconstruction and reconstruction of their teacher identities (Kamoga & Varea, 2022). In a nutshell, PE subject matter and PE teachers' identities are being challenged and experiencing unexpected metamorphoses amid this global crisis.

Article
Publication date: 5 September 2021

Nur Shahira Abdul Nasir, Revathy Deivasigamani, Muhammad Khairulanwar Abdul Rahim, Siti Nur Ashakirin Mohd Nashruddin, Azrul Azlan Hamzah, M. Farhanulhakim M. Razip Wee and Muhamad Ramdzan Buyong

The purpose of this paper is to visualize protein manipulation using dielectrophoresis (DEP) as a substantial perspective on being an effective protein analysis and biosensor…

90

Abstract

Purpose

The purpose of this paper is to visualize protein manipulation using dielectrophoresis (DEP) as a substantial perspective on being an effective protein analysis and biosensor method as DEP is able to be used as a means for manipulation, fractionation, pre-concentration and separation. This research aims to quantify DEP using an electrochemical technique known as cyclic voltammetry (CV), as albumin is non-visible without any fluorescent probe or dye.

Design/methodology/approach

The principles of DEP were generated by an electric field on tapered DEP microelectrodes. The principle of CV was analysed using different concentrations of albumin on a screen-printed carbon electrode. Using preliminary data from both DEP and CV methods as a future prospect for the integration of both techniques to do electrical quantification of DEP forces.

Findings

The size of the albumin is known to be 0.027 µm. Engineered polystyrene particle of size 0.05 µm was selected to mimic the DEP actuation of albumin. Positive DEP of the sample engineered polystyrene particle was able to be visualized clearly at 10 MHz supplied with 20 Vpp. However, negative DEP was not able to be visualized because of the limitation of the apparatus. However, albumin was not able to be visualized under the fluorescent microscope because of its translucent properties. Thus, a method of electrical quantification known as the CV technique is used. The detection of bovine serum albumin (BSA) using the CV method is successful. As the concentration of BSA increases, the peak current obtained from the voltammogram decreases. The peak current can be an indicator of DEP response as it correlates to the adsorption of the protein onto the electrodes. The importance of the results from both CV and DEP shows that the integration of both techniques is possible.

Originality/value

The integration of both methods could give rise to a new technique with precision to be implemented into the dialyzers used in renal haemodialysis treatment for manipulation and sensing of protein albumin.

Article
Publication date: 20 September 2023

Shamima Khatoon and Gufran Ahmad

The hygroscopic properties of 3D-printed filaments and moisture absorption itself during the process result in dimensional inaccuracy, particularly for nozzle movement along the…

Abstract

Purpose

The hygroscopic properties of 3D-printed filaments and moisture absorption itself during the process result in dimensional inaccuracy, particularly for nozzle movement along the x-axis and for micro-scale features. In view of that, this study aims to analyze in depth the dimensional errors and deviations of the fused filament fabrication (FFF)/fused deposition modeling (FDM) 3D-printed micropillars (MPs) from the reference values. A detailed analysis into the variability in printed dimensions below 1 mm in width without any deformations in the printed shape of the designed features, for challenging filaments like polymethyl methacrylate (PMMA) has been done. The study also explores whether the printed shape retains the designed structure.

Design/methodology/approach

A reference model for MPs of width 800 µm and height 2,000 µm is selected to generate a g-code model after pre-processing of slicing and meshing parameters for 3D printing of micro-scale structure with defined boundaries. Three SETs, SET-A, SET-B and SET-C, for nozzle diameter of 0.2 mm, 0.25 mm and 0.3 mm, respectively, have been prepared. The SETs containing the MPs were fabricated with the spacing (S) of 2,000 µm, 3,200 µm and 4,000 µm along the print head x-axis. The MPs were measured by taking three consecutive measurements (top, bottom and middle) for the width and one for the height.

Findings

The prominent highlight of this study is the successful FFF/FDM 3D printing of thin features (<1mm) without any deformation. The mathematical analysis of the variance of the optical microscopy measurements concluded that printed dimensions for micropillar widths did not vary significantly, retaining more than 65% of the recording within the first standard deviation (SD) (±1 s). The minimum value of SD is obtained from the samples of SET-B, that is, 31.96 µm and 35.865 µm, for height and width, respectively. The %RE for SET-B samples is 5.09% for S = 2,000µm, 3.86% for S = 3,200µm and 1.09% for S = 4,000µm. The error percentage is so small that it could be easily compensated by redesigning.

Research limitations/implications

The study does not cover other 3D printing techniques of additive manufacturing like stereolithography, digital light processing and material jetting.

Practical implications

The presented study can be potentially implemented for the rapid prototyping of microfluidics mixer, bioseparator and lab-on-chip devices, both for membrane-free bioseparation based on microfiltration, plasma extraction from whole blood, size-selection trapping of unwanted blood cells, and also for membrane-based plasma extraction that requires supporting microstructures. Our developed process may prove to be far more economical than the other existing techniques for such applications.

Originality/value

For the first time, this work presents a comprehensive analysis of the fabrication of micropillars using FDM/FFF 3D printing and PMMA in filament form. The primary focus of the study is to minimize the dimensional inaccuracies in the 3D printed devices containing thin features, especially in the area of biomedical engineering, by delivering benefits from the choice of the parameters. Thus, on the basis of errors and deviations, a thorough comparison of the three SETs of the fabricated micropillars has been done.

Article
Publication date: 11 March 2021

Miao-Tzu Lin

Flexible hydrogenated amorphous silicon (a-Si:H) solar cells have many advantages, including lower weight, good flexibility and light sensitivity. Moreover, a-Si:H solar cells can…

Abstract

Purpose

Flexible hydrogenated amorphous silicon (a-Si:H) solar cells have many advantages, including lower weight, good flexibility and light sensitivity. Moreover, a-Si:H solar cells can be used as sensors, as indoor light sources and can also generate electricity. These solar cells are suitable for the design of portable systems and curved materials. The purpose of this study was to integrate flexible a-Si:H solar cells and wearable technology and to apply the dual functions of photovoltaics and photo sensors to smart clothing and eyewear.

Design/methodology/approach

The integration of flexible a-Si:H solar cells and tri-colour light-emitting diodes (LEDs) was used to develop smart auto-flashing clothing. In addition, we combined flexible a-Si:H solar cells and twisted nematic (TN) liquid crystal (LC) cells to design smart self-activation eyewear.

Findings

The maximum power resistance value of flexible a-Si:H solar cells was used to deduce the equation of solar cell voltage value generated by different percentages of SUN (100% SUN means 100 mW/cm2). A solar cell was used as a photo sensor that connects a resistor in a series to the Arduino to detect the voltage value, and then different percentages of SUN are calculated from the equation. Applying the deduced equation to the smart phone APP and Arduino code, we developed a human–machine interface (HMI) to facilitate user operation.

Originality/value

In this study, the flexible a-Si:H solar cell performs the function of not only photovoltaic power generation but also that of a photo sensor. The smart auto-flashing clothing is suitable for traffic guides, joggers and people engaging in other night activities. This smart self-activating eyewear can adjust to light and protect the eyes.

Details

International Journal of Clothing Science and Technology, vol. 34 no. 1
Type: Research Article
ISSN: 0955-6222

Keywords