Search results

1 – 2 of 2
Per page
102050
Citations:
Loading...
Access Restricted. View access options
Article
Publication date: 17 October 2019

Zohir Younsi, Lounes Koufi and Hassane Naji

A comprehensive investigation on the outlet air position effects on the thermal comfort and air quality has been achieved. In addition, airflow and temperature distributions in…

212

Abstract

Purpose

A comprehensive investigation on the outlet air position effects on the thermal comfort and air quality has been achieved. In addition, airflow and temperature distributions in ventilated cavities filled with an air-CO2 mixture with mixed convection are predicted. The airflow enters from the cavity through an opening in the lower side of the left vertical wall and exits through the opening in one wall of the cavity. This paper aims to investigate the outlet location effect, four different placement configurations of output ports are considered. Three of them are placed on the upper side and the fourth on top of the opposite side of the inlet opening. A uniform heat and CO2 contaminant source are applied on the left vertical wall, while the remaining walls are impermeable and adiabatic to heat and solute. The cooling efficiency inside the enclosure and the average fluid temperature are computed for different Reynolds and Rayleigh numbers to find the most suitable fluid outlet position that ensures indoor comfortable conditions while effectively removing heat and the contaminant. This is demonstrated by three relevant indices, namely, the effectiveness for heat removal, the contaminant removal and the index of indoor air quality.

Design/methodology/approach

The simulations were performed via the finite-volume scSTREAM CFD solver V11. Three different values of CO2 amount are considered, namely, 103, 2 × 103 and 3 × 103 ppm, the Reynolds number being in the range 100 ≤ Re ≤ 800.

Findings

Based on the findings obtained, it is the configuration whose air outlet is placed near the heat source and the contaminant, which provides a better air distribution and a ventilation efficiency compared to the others ventilation strategies.

Originality/value

The studies on heat and mass transfers by natural and forced convection in ventilated cavities remain a fruitful research topic. Thereby, such a study deals with different ventilation strategies through cavities containing an air-CO2 mixture subjected to a mixed regime. In particular, the air inlet velocity and contaminant sources’ effects on thermal comfort and air quality have been investigated.

Details

International Journal of Numerical Methods for Heat & Fluid Flow, vol. 29 no. 11
Type: Research Article
ISSN: 0961-5539

Keywords

Access Restricted. View access options
Article
Publication date: 6 June 2016

Chahinez Ghernoug, Mahfoud Djezzar, Hassane Naji and Abdelkarim Bouras

The purpose of this paper is to numerically study the double-diffusive natural convection within an eccentric horizontal cylindrical annulus filled with a Newtonian fluid. The…

225

Abstract

Purpose

The purpose of this paper is to numerically study the double-diffusive natural convection within an eccentric horizontal cylindrical annulus filled with a Newtonian fluid. The annulus walls are maintained at uniform temperatures and concentrations so as to induce aiding thermal and mass buoyancy forces within the fluid. For that, this simulation span a moderate range of thermal Rayleigh number (100RaT100,000), Lewis (0.1Le10), buoyancy ratio (0N5) and Prandtl number (Pr=0.71) to examine their effects on flow motion and heat and mass transfers.

Design/methodology/approach

A finite volume method in conjunction with the successive under-relaxation algorithm has been developed to solve the bipolar equations. These are written in dimensionless form in terms of vorticity, stream function, temperature and concentration. Beforehand, the implemented computer code has been validated through already published findings in the literature. The isotherms, streamlines and iso-concentrations are exhibited for various values of Rayleigh and Lewis numbers, and buoyancy ratio. In addition, heat and mass transfer rates in the annulus are translated in terms of Nusslet and Sherwood numbers along the enclosure’s sides.

Findings

It is observed that, for the range of parameters considered here, the results show that the average Sherwood number increases with, while the average Nusselt number slightly dips as the Lewis number increases. It is also found that, under the convective mode, the local Nusselt number (or Sherwood) increases with the buoyancy ratio. Likewise, according to Lewis number’s value, the flow pattern is either symmetric and stable or asymmetric and random. Besides that, the heat transfer is transiting from a conductive mode to a convective mode with increasing the thermal Rayleigh number, and the flow structure and the rates of heat and mass transfer are significantly influenced by this parameter.

Research limitations/implications

The range of the Rayleigh number considered here covers only the laminar case, with some constant parameters, namely the Prandtl number (Pr = 0.71), and the tilt angle (α=90°). The analysis here is only valid for steady, two-dimensional, laminar and aiding flow within an eccentric horizontal cylindrical annulus. This motivates further investigations involving other relevant parameters as N (opposite flows), Ra, Pr, Le, the eccentricity, the tilt angle, etc.

Practical implications

An original framework for handling the double-diffusive natural convection within annuli is available, based on the bipolar equations. In addition, the achievement of this work could help researchers design thermal systems supported by annulus passages. Applications of the results can be of value in various arrangements such as storage of liquefied gases, electronic cable cooling systems, nuclear reactors, underground disposal of nuclear wastes, manifolds of solar energy collectors, etc.

Originality/value

Given the geometry concerned, the bipolar coordinates have been used to set the inner and outer walls boundary conditions properly without interpolation. In addition, since studies on double-diffusive natural convection in annuli are lacking, the obtained results may be of interest to handle other configurations (e.g., elliptical-shaped speakers) with other boundary conditions.

Details

International Journal of Numerical Methods for Heat & Fluid Flow, vol. 26 no. 5
Type: Research Article
ISSN: 0961-5539

Keywords

1 – 2 of 2
Per page
102050