Search results

1 – 6 of 6
Article
Publication date: 26 April 2013

J.K. Atkinson, M. Glanc, M. Prakorbjanya, M. Sophocleous, R.P. Sion and E. Garcia‐Breijo

The purpose of this paper is to report thick film environmental and chemical sensor arrays designed for deployment in both subterranean and submerged aqueous applications.

Abstract

Purpose

The purpose of this paper is to report thick film environmental and chemical sensor arrays designed for deployment in both subterranean and submerged aqueous applications.

Design/methodology/approach

Various choices of materials for reference electrodes employed in these different applications have been evaluated and the responses of the different sensor types are compared and discussed.

Findings

Results indicate that the choice of binder materials is critical to the production of sensors capable of medium term deployment (e.g. several days) as the binders not only affect the tradeoff between hydration time and drift but also have a significant bearing on device sensitivity and stability. Sensor calibration is shown to remain an issue with long‐term deployments (e.g. several weeks) but this can be ameliorated in the medium term with the use of novel device fabrication and packaging techniques.

Originality/value

The reported results indicate that is possible through careful choice of materials and fabrication methods to achieve near stable thick film reference electrodes that are suitable for use in solid state chemical sensors in a variety of different application areas.

Details

Microelectronics International, vol. 30 no. 2
Type: Research Article
ISSN: 1356-5362

Keywords

Article
Publication date: 10 May 2011

J.K. Atkinson, M. Glanc, P. Boltryk, M. Sophocleous and E. Garcia‐Breijo

The purpose of this paper is to show how the fabrication parameters of screen‐printed thick‐film reference electrodes have been experimentally varied and their effect on device…

Abstract

Purpose

The purpose of this paper is to show how the fabrication parameters of screen‐printed thick‐film reference electrodes have been experimentally varied and their effect on device characteristics investigated.

Design/methodology/approach

The tested devices were fabricated as screen‐printed planar structures consisting of a silver back contact, a silver/silver chloride interfacial layer and a final salt reservoir layer containing potassium chloride. The fabrication parameters varied included deposition method and thickness, salt concentration and binder type used for the final salt reservoir layer. Characterisation was achieved by monitoring the electrode potentials as a function of time following initial immersion in test fluids in order to ascertain initial hydration times, subsequent electrode drift rates and useful lifetime of the electrodes. Additionally, the effect of fabrication parameter variation on electrode stability and their response time in various test media was also investigated.

Findings

Results indicate that, although a trade‐off exists between hydration times and drift rate that is dependent on device thickness, the initial salt concentration levels and binder type also have a significant bearing on the practical useful lifetime. Generally speaking, thicker devices take longer to hydrate but have longer useful lifetimes in a given range of chloride environments. However, the electrode stability and response time is also influenced by the type of binder material employed for the final salt reservoir layer.

Originality/value

The reported results help to explain better the behaviour of thick‐film reference electrodes and contribute towards the optimisation of their design and fabrication for use in solid‐state chemical sensors.

Details

Microelectronics International, vol. 28 no. 2
Type: Research Article
ISSN: 1356-5362

Keywords

Article
Publication date: 5 May 2015

Eduardo Garcia-Breijo, Gema Prats-Boluda, Jose Vicente Lidon-Roger, Yiyao Ye-Lin and Javier Garcia-Casado

This paper aims to present a comparison between three types of manufacturing techniques, namely, screen-printed, inkjet and gravure, using different types of inks, for the…

347

Abstract

Purpose

This paper aims to present a comparison between three types of manufacturing techniques, namely, screen-printed, inkjet and gravure, using different types of inks, for the implementation of concentric ring electrodes which permit estimation of Laplacian potential on the body surface.

Design/methodology/approach

Flexible concentric ring electrodes not only present lower skin–electrode contact impedance and lower baseline wander than rigid electrodes but are also less sensitive to interference and motion artefacts. The above three techniques allow printing of conductive inks on flexible substrates, and with this work, the authors aim to study which is the best technique and ink to obtain the best electrode response.

Findings

From the results obtained regarding ink thickness, resistivity, electrode resistance and other performance parameters derived from electrocardiographic signal recording tests, it can be said that concentric electrodes using the screen-printing and inkjet techniques are suitable for non-invasive bioelectric signal acquisition.

Originality/value

The development of new types of inks and substrates for the electronics industry and the adaptation of new manufacturing techniques allow for an improvement in the development of electrodes and sensors.

Details

Microelectronics International, vol. 32 no. 2
Type: Research Article
ISSN: 1356-5362

Keywords

Open Access
Article
Publication date: 1 March 2024

Quoc Duy Nam Nguyen, Hoang Viet Anh Le, Tadashi Nakano and Thi Hong Tran

In the wine industry, maintaining superior quality standards is crucial to meet the expectations of both producers and consumers. Traditional approaches to assessing wine quality…

1071

Abstract

Purpose

In the wine industry, maintaining superior quality standards is crucial to meet the expectations of both producers and consumers. Traditional approaches to assessing wine quality involve labor-intensive processes and rely on the expertise of connoisseurs proficient in identifying taste profiles and key quality factors. In this research, we introduce an innovative and efficient approach centered on the analysis of volatile organic compounds (VOCs) signals using an electronic nose, thereby empowering nonexperts to accurately assess wine quality.

Design/methodology/approach

To devise an optimal algorithm for this purpose, we conducted four computational experiments, culminating in the development of a specialized deep learning network. This network seamlessly integrates 1D-convolutional and long-short-term memory layers, tailor-made for the intricate task at hand. Rigorous validation ensued, employing a leave-one-out cross-validation methodology to scrutinize the efficacy of our design.

Findings

The outcomes of these e-demonstrates were subjected to meticulous evaluation and analysis, which unequivocally demonstrate that our proposed architecture consistently attains promising recognition accuracies, ranging impressively from 87.8% to an astonishing 99.41%. All this is achieved within a remarkably brief timeframe of a mere 4 seconds. These compelling findings have far-reaching implications, promising to revolutionize the assessment and tracking of wine quality, ultimately affording substantial benefits to the wine industry and all its stakeholders, with a particular focus on the critical aspect of VOCs signal analysis.

Originality/value

This research has not been published anywhere else.

Details

Applied Computing and Informatics, vol. ahead-of-print no. ahead-of-print
Type: Research Article
ISSN: 2634-1964

Keywords

Article
Publication date: 30 October 2023

Aizhan Doshibekova, Indira Jurinskaya, Salikh Tashpulatov, Raushan Zhilisbayeva, Lazzat Sarttarova, Rustam Akbarov and Marzhan Kalmakhanova

This paper aims to study the possibility of electroplating copper coatings on chemically and chemical-galvanically nickel-plated acrylic fibers, to be further processed into yarn…

Abstract

Purpose

This paper aims to study the possibility of electroplating copper coatings on chemically and chemical-galvanically nickel-plated acrylic fibers, to be further processed into yarn, fabrics, knitwear and nonwoven materials.

Design/methodology/approach

Electrically conductive fibers with different copper contents have been obtained, and the effect of electrolyte pH, its composition, current strength at the first and second cathodes, as well as the metallization time on the electrophysical, physical and mechanical properties of copper-containing fibers, has been studied.

Findings

The studies have shown that with an increase in the copper content, the electrical conductivity, the uniformity of the coating and the uniformity of the electrophysical properties (for chemical-galvanically nickel-plated fiber) increase. In the case of copper plating of chemically nickel-plated fiber, the coefficient of variation in electrical resistance increases with increasing plating time, even though the copper content increases, and the coefficient of variation in copper content and electrical resistance decreases. The physical and mechanical properties of copper-containing fibers differ slightly from the original (subjected to copper plating) and industrial Nitron fibers. With copper plating, the strength of the fiber practically does not decrease, and the elongation decreases somewhat, compared with the mass-produced Nitron fiber.

Originality/value

The physical and mechanical properties of copper-containing fibers are quite high, which makes it possible to be successfully further processed into yarn, fabrics, knitwear and nonwoven materials.

Details

Research Journal of Textile and Apparel, vol. 29 no. 1
Type: Research Article
ISSN: 1560-6074

Keywords

Article
Publication date: 18 November 2024

Sudev Dutta, Sudhanshu Dogra and Sumit Sharma

The demand of species monitoring for the benefit of various sectors such as industrial, medicinal and ecological has surged rapidly in the recent past. Therefore, the purpose of…

Abstract

Purpose

The demand of species monitoring for the benefit of various sectors such as industrial, medicinal and ecological has surged rapidly in the recent past. Therefore, the purpose of this paper is to articulate the major developments in synthesizing conductive inks for the structurization of miniaturized as well as disposable or reusable electrochemical equipments.

Design/methodology/approach

This section is not applicable to a review paper.

Findings

Numerous times the need for the use point becomes significant for achieving accurate as well as swift quantification. As an alternate, the wearable and effectual reuseable electrochemical sensors are being practiced. The technique of fabricating devices using conductive inks encompasses novelty, as it provides flexibility in designing the electrodes. The increase in the popularity of inks development is governed by its features of simplicity, reduced cost and waste generation, high production and eco-friendly engineering procedures. Further, the electrochemistry aspects of conductive inks highlighting the importance of their compounds and binders has also been discussed emphasizing on the conductive materials.

Originality/value

This paper is an original review work. This paper will be helpful for manufacturers/researchers from smart wearable textile sector in envisaging innovative developing techniques of sensors as well as biosensors through conductive inks.

Details

Research Journal of Textile and Apparel, vol. ahead-of-print no. ahead-of-print
Type: Research Article
ISSN: 1560-6074

Keywords

1 – 6 of 6