Nidal H. Abu-Hamdeh, Ömer Akbal, Hakan F. Öztop, Abdullah M. Abusorrah and Mohannad M. Bayoumi
The purpose of this paper is to solve the problem of a three-dimensional computational analysis for an elliptic-shaped cavity in a pipe under constant temperature.
Abstract
Purpose
The purpose of this paper is to solve the problem of a three-dimensional computational analysis for an elliptic-shaped cavity in a pipe under constant temperature.
Design/methodology/approach
The three-dimensional computational solution of governing equations was performed by using finite volume method with different temperature difference.
Findings
The parafin wax was chosen as a phase change material (PCM), and melting fraction, streamlines and isotherms are formed for different time step. It is found that position B give better results than that of position A, and temperature difference effects the duration of melting of PCM.
Originality/value
The three-dimensional analysis of melting in an ellipsoidal pipe with inner pipe with higher temperature is the main originality of this work.
Details
Keywords
Hakan F. Oztop, Rıdvan Özgül and Fatih Selimefendigil
The purpose of this paper is to analyze the performance of a data center and thermal management by using phase change material (PCM). Numerical studies were conducted for two…
Abstract
Purpose
The purpose of this paper is to analyze the performance of a data center and thermal management by using phase change material (PCM). Numerical studies were conducted for two dimensional model of data center and installation of PCM at different locations.
Design/methodology/approach
Finite volume method was used for the unsteady problem, while impacts of air velocity and PCM location on the flow field, thermal pattern variations and phase change dynamics were evaluated. Three different locations of the PCM were considered while air velocity was also varied during the simulation. Thermal field variations and cooling performance of the system for different PCM location scenarios were compared.
Findings
It was observed that the installation of the PCM has significant impacts on the vortex formation, thermal field variation within the system and its performance. The left, right and top wall installation of the PCM changed the thermal patterns near the heat cell of the data centre. The phase change process is fast for the upper wall installation of the PCM, while the discrepancy of the melt fraction dynamics between different air flow at this position is minimum. The case where PCM placed in the upper wall at the highest air velocity is the best configuration in terms of heat storage. The utilization of PCM and changing its locations provide an excellent tool for thermal management and cooling performance of data centre.
Originality/value
Results of this study can be used for initial design and optimization of cooling systems for thermal management of data centers while the importance of the high-performance computing becomes very crucial for the advanced simulations in different technological applications.