Search results

1 – 1 of 1
Open Access
Article
Publication date: 18 April 2023

Worapan Kusakunniran, Pairash Saiviroonporn, Thanongchai Siriapisith, Trongtum Tongdee, Amphai Uraiverotchanakorn, Suphawan Leesakul, Penpitcha Thongnarintr, Apichaya Kuama and Pakorn Yodprom

The cardiomegaly can be determined by the cardiothoracic ratio (CTR) which can be measured in a chest x-ray image. It is calculated based on a relationship between a size of heart…

3663

Abstract

Purpose

The cardiomegaly can be determined by the cardiothoracic ratio (CTR) which can be measured in a chest x-ray image. It is calculated based on a relationship between a size of heart and a transverse dimension of chest. The cardiomegaly is identified when the ratio is larger than a cut-off threshold. This paper aims to propose a solution to calculate the ratio for classifying the cardiomegaly in chest x-ray images.

Design/methodology/approach

The proposed method begins with constructing lung and heart segmentation models based on U-Net architecture using the publicly available datasets with the groundtruth of heart and lung masks. The ratio is then calculated using the sizes of segmented lung and heart areas. In addition, Progressive Growing of GANs (PGAN) is adopted here for constructing the new dataset containing chest x-ray images of three classes including male normal, female normal and cardiomegaly classes. This dataset is then used for evaluating the proposed solution. Also, the proposed solution is used to evaluate the quality of chest x-ray images generated from PGAN.

Findings

In the experiments, the trained models are applied to segment regions of heart and lung in chest x-ray images on the self-collected dataset. The calculated CTR values are compared with the values that are manually measured by human experts. The average error is 3.08%. Then, the models are also applied to segment regions of heart and lung for the CTR calculation, on the dataset computed by PGAN. Then, the cardiomegaly is determined using various attempts of different cut-off threshold values. With the standard cut-off at 0.50, the proposed method achieves 94.61% accuracy, 88.31% sensitivity and 94.20% specificity.

Originality/value

The proposed solution is demonstrated to be robust across unseen datasets for the segmentation, CTR calculation and cardiomegaly classification, including the dataset generated from PGAN. The cut-off value can be adjusted to be lower than 0.50 for increasing the sensitivity. For example, the sensitivity of 97.04% can be achieved at the cut-off of 0.45. However, the specificity is decreased from 94.20% to 79.78%.

Details

Applied Computing and Informatics, vol. ahead-of-print no. ahead-of-print
Type: Research Article
ISSN: 2634-1964

Keywords

1 – 1 of 1