1 – 1 of 1Harkaitz Garcia, María Victoria Biezma, Jesús Cuadrado and Eduardo Rojí
The purpose of this paper is to analyze a new structural design applied in industrial frames using two type of steels (S275 and fire resistant (FR)) with different mechanical…
Abstract
Purpose
The purpose of this paper is to analyze a new structural design applied in industrial frames using two type of steels (S275 and fire resistant (FR)) with different mechanical resistance against fire. To do it, the authors have taken into account variables such as intrinsic metallic design, span length, intumescent paint thickness, and fire time exposure, which offers information about new scenarios of design in industry.
Design/methodology/approach
The key methodology followed has taken into account a modeling program that uses the following variables: 25 and 35 m of span, 45 and 60 fire exposure times, and seven different intumescent paint thickness. An optimum structural design has been evaluated by discretization of each scenario with the particular type of steel, S275 and FR. The obtained approach could be a good guideline for future designs.
Findings
The results and analysis have shown a very good and valid idea of a new structural typology using optimum intumescent paint thickness into the final design of the industrial frame considering that it has two different types of steel. It is in realty a handicap since usually mechanical engineers employ structural steel without paying attention to this new feature.
Practical implications
Cheaper structural designs could be obtained using the two different types of steel considering the proper positioning into the full building.
Originality/value
The validity of design of two types of steel plus intumescent paint in building construction has been shown, and this study will encourage designers to use it, in particular in buildings with high fire risk.