1 – 2 of 2Wantanee Phanprasit, Kanchanok Songpek, Vorakamol Boonyayothin and Dusit Sujirarat
The purpose of this paper is to explore inhalation levels and dermal exposure to toluene among printing workers who wore no personal protective equipment; it is conducted in a…
Abstract
Purpose
The purpose of this paper is to explore inhalation levels and dermal exposure to toluene among printing workers who wore no personal protective equipment; it is conducted in a plastic bag factory. Using a charcoal cloth pad (CCP) as a dermal sampler to assess skin permeation of liquid toluene is also investigated.
Design/methodology/approach
In total, 27 stationary air samples as well as urine and dermal samples were collected over 9 days from 11 printing workers. Six pieces of CCP were wrapped on each of the workers’ fingers for the dermal sample collection. Air samples were collected and analyzed according to NIOSH No. 1501, and 65 post-shift urine samples were collected and analyzed using gas chromatography equipped with headspace sampler (GC-HS/FID). Multiple linear regression was employed to analyze the association between the studied variables.
Findings
The mean (SD) urinary toluene (UTol) level was 13.42 (9.72) ug/L. Toluene on the CCP (TolCCP) was a meaningful predictor for UTol (p-value=0.027) with r and r2 values of 0.441 and 0.195, respectively. The r and r2 of the model using the toluene time-weighted average concentrations in air were 0.739 and 0.546, respectively. The absorbed dose of toluene determined from the TolCCP ranged from 1.05 to 91.94 mg, accounting for 12.3 percent of the threshold limit value (TLV).
Originality/value
Dermal exposure was insignificant when workers wore respirators, but when not, dermal absorption could contribute to the overall uptake and exposure above the TLV. Appropriate gloves should be assigned to the workers to reduce dermal exposure to toluene.
Details
Keywords
Watcharaporn Wongsakoonkan, Sumate Pengpumkiat, Vorakamol Boonyayothin, Chaiyanun Tangtong, Wisanti Laohaudomchok and Wantanee Phanprasit
The purpose of this study was to develop an accurate, selective, low-cost and user-friendly colorimetric pad to detect formaldehyde at low concentration.
Abstract
Purpose
The purpose of this study was to develop an accurate, selective, low-cost and user-friendly colorimetric pad to detect formaldehyde at low concentration.
Design/methodology/approach
1-phenyl-1,3-butanedione, a reactive chemical, was selected to develop the colorimetric pad for indoor air formaldehyde measurement. Silica nanoparticle impregnated with the reactive chemical was coated on the cellulose filter surface to increase the reactive site. A certified formaldehyde permeation tube was used to generate six varied concentrations between 0.01 and 0.10 ppm in a test chamber. The color intensity on the pads was measured using an image processing program to produce a formaldehyde concentration reading chart. The colorimetric pad was tested for optimum reaction time, accuracy, precision, stability, selectivity and shelf life.
Findings
The color of the pads changed from white to yellow and the color intensity varied with the concentrations and appeared to be stable after exposure to formaldehyde for 8 hours. At room temperature, the stability of the pad was 7 days, and shelf life was 120 days. The accuracy, precision and bias of the pad were 12.38%, 0.032 and 6.0%, respectively. Carbonyl compounds, benzene and toluene did not interfere with the reading of this developed colorimetric pad.
Originality/value
The developed colorimetric pad meets NIOSH's criteria for an overall accuracy of ±25%, bias = 10%. They were accurate at low concentrations, user-friendly and had low cost compared to an electronic direct reading instrument (cost of chemicals and materials was 21.50 Bath or 0.69 USD per piece) so that favorable for the use of general people for health protection.