Publication date: 22 November 2023

Dravesh Yadav, Ravi Sastri Ayyagari and Gaurav Srivastava

This paper numerically investigates the effect of cavity radiation on the thermal response of hollow aluminium tubes and facade systems subjected to fire.

78

Abstract

Purpose

This paper numerically investigates the effect of cavity radiation on the thermal response of hollow aluminium tubes and facade systems subjected to fire.

Design/methodology/approach

Finite element simulations were performed using ABAQUS 6.14. The accuracy of the numerical model was established through experimental and numerical results available in the literature. The proposed numerical model was utilised to study the effect of cavity radiation on the thermal response of aluminium hollow tubes and facade system. Different scenarios were considered to assess the applicability of the commonly used lumped capacitance heat transfer model.

Findings

The effects of cavity radiation were found to be significant for non-uniform fire exposure conditions. The maximum temperature of a hollow aluminium tube with 1-sided fire exposure was found to be 86% greater when cavity radiation was considered. Further, the time to attain critical temperature under non-uniform fire exposure, as calculated from the conventional lumped heat capacity heat transfer model, was non-conservative when compared to that predicted by the proposed simulation approach considering cavity radiation. A metal temperature of 550 °C was attained about 18 min earlier than what was calculated by the lumped heat capacitance model.

Research limitations/implications

The present study will serve as a basis for the study of the effects of cavity radiation on the thermo-mechanical response of aluminium hollow tubes and facade systems. Such thermo-mechanical analyses will enable the study of the effects of cavity radiation on the failure mechanisms of facade systems.

Practical implications

Cavity radiation was found to significantly affect the thermal response of hollow aluminium tubes and façade systems. In design processes, it is essential to consider the potential consequences of non-uniform heating situations, as they can have a significant impact on the temperature of structures. It was also shown that the use of lumped heat capacity heat transfer model in cases of non-uniform fire exposure is unsuitable for the thermal analysis of such systems.

Originality/value

This is the first detailed investigation of the effects of cavity radiation on the thermal response of aluminium tubes and façade systems for different fire exposure conditions.

Details

Journal of Structural Fire Engineering, vol. 15 no. 3
Type: Research Article
ISSN: 2040-2317

Keywords

Access Restricted. View access options
Article
Publication date: 19 February 2018

Adji Achmad Rinaldo Fernandes, Raffles Brotestes Panjaitan and Solimun

The purpose of this research is to analyze the effect of community and company participation on corporate governance and forest fire prevention in the forest zone, which has a…

836

Abstract

Purpose

The purpose of this research is to analyze the effect of community and company participation on corporate governance and forest fire prevention in the forest zone, which has a high level of vulnerability to forest fires, in Indonesia.

Design/methodology/approach

The survey method in this research used a quantitative approach with the survey method, with the sample being forest areas having a high level of vulnerability to forest fires in Indonesia. This study used a questionnaire instrument and was conducted from January to March 2017. The research population was 105 villages located in forest areas in six major provinces known to endure the largest forest fires in Indonesia. From a total population of 258 villages, 52 were selected for this study. The proportional random sampling area technique was used. The data analysis methods selected in this research were descriptive analysis and inferential statistical analysis using the partial least squares method.

Findings

Community and company participation has a significant effect on the implementation of good governance. The implementation of good governance has a significant effect and community and company participation has no direct effect on the forest fire policy, but through good governance mediation, an indirect effect of community participation on the forest fire policy is seen.

Originality/value

No previous research has comprehensively studied the role of community and company participation and implementation of good forest fire governance on the forest fire policy.

Details

Journal of Science and Technology Policy Management, vol. 10 no. 1
Type: Research Article
ISSN: 2053-4620

Keywords

Access Restricted. View access options
Article
Publication date: 13 June 2016

Mahmud M.S. Dwaikat

Different approaches, originally developed for ambient conditions, exist in current codes and standards for incorporating the effect of moment–shear (M–V) interaction on the…

137

Abstract

Purpose

Different approaches, originally developed for ambient conditions, exist in current codes and standards for incorporating the effect of moment–shear (M–V) interaction on the plastic-carrying capacity of wide-flanged (WF) steel sections. There is a lack of experimental and theoretical studies that address this issue under fire conditions.

Design/methodology/approach

The current paper presents a numerical study investigating the effect of fire exposure on the plastic M–V capacity curves of doubly symmetrical, WF, hot-rolled steel sections. Validated high-fidelity finite element (FE) models constructed via ANSYS are used to study the effect M–V interaction on the plastic capacity of WF sections. Also, a simplified plastic sectional analysis, intended to be used by engineering practitioners, is proposed for generating the plastic M–V interaction curves.

Findings

The study shows that the fire-induced non-uniform heating of the section plates affects the shape of the plastic M–V interaction capacity curves. Comparison of different methods against FE results shows that the method specified in the Eurocode is very conservative at room-temperature, but it turns out to be barely sufficiently conservative under fire conditions.

Originality/value

It is well noted that lack of fire tests on the M–V interaction, including the stability of the plates of steel sections under fire, make it difficult to reach a definite assessment on the effect of M–V interaction on the bearing capacity of steel beams.

Details

Journal of Structural Fire Engineering, vol. 7 no. 2
Type: Research Article
ISSN: 2040-2317

Keywords

Access Restricted. View access options
Article
Publication date: 28 May 2020

András Jakab, Viktor Hlavicka, Ágoston Restás and Eva Lubloy

During the building designing, it is very important to deal with the fire resistance of the structures. The designed materials for escape routes should be selected to ensure the…

176

Abstract

Purpose

During the building designing, it is very important to deal with the fire resistance of the structures. The designed materials for escape routes should be selected to ensure the usability of the structures until the time of escape. Planning affects the glass structures similarly, so these can also be partition walls and load bearing structures, although the latter is less applied on escape routes. The heat protection of the glasses can be improved with heat-protective foils, while fire protection is provided by gel intumescent material.

Design/methodology/approach

To research the topic of fire resistance, laboratory experiments were carried out on small-scaled glass elements with thermal protection foil at Budapest University of Technology and Economics at the Department of Construction Materials and Technologies.

Findings

Fire protection of small model specimens was tested with blowtorch fire and furnace heat load. During the experiments, six foils were tested. Single pane glass, double layered and triple glazed specimens were tested with blowtorch fire.

Originality/value

Fire protection of small model specimens was tested with blowtorch fire and furnace heat load. During the experiments, six foils were tested. Single pane glass, double layered and triple glazed specimens were tested with blowtorch fire. In case of heat-protected glazing, the foils on the “protected” side of the single pane glass do not have a fire protection effect based on blowtorch fire test. For double glassed specimens, the P35 foil has a perceptible effect, even for the requirements of the flame breakthrough (E, integrity), when the foil is placed on the inner side (position 3) of the second glass layer. The stratification of each triple glazed specimens was effective against blowtorch fire load (3 M, S4&P35), so (EI, integrity and isolation) it can meet the requirements of flame breakthrough and thermal insulation.

Details

Journal of Structural Fire Engineering, vol. 11 no. 3
Type: Research Article
ISSN: 2040-2317

Keywords

Access Restricted. View access options
Article
Publication date: 22 April 2022

Mhd Anwar Orabi, Jin Qiu, Liming Jiang and Asif Usmani

Reinforced concrete slabs in fire have been heavily studied over the last three decades. However, most experimental and numerical work focuses on long-duration uniform exposure to…

285

Abstract

Purpose

Reinforced concrete slabs in fire have been heavily studied over the last three decades. However, most experimental and numerical work focuses on long-duration uniform exposure to standard fire. Considerably less effort has been put into investigating the response to localised fires that result in planarly non-uniform temperature distribution in the exposed elements.

Design/methodology/approach

In this paper, the OpenSees for Fire framework for modelling slabs under non-uniform fire exposure is presented, verified against numerical predictions by Abaqus and then validated against experimental tests. The thermal wrapper developed within OpenSees for Fire is then utilised to apply localised fire exposure to the validated slab models using the parameters of an experimentally observed localised fire. The effect of the smoke layer is also considered in this model and shown to significantly contribute to the thermal and thus thermo-mechanical response of slabs. Finally, the effect of localised fire heat release rate (HRR) and boundary conditions are studied.

Findings

The analysis showed that boundary conditions are very important for the response of slabs subject to localised fire, and expansive strains may be accommodated as deflections without severely damaging the slab by considering the lateral restraint.

Originality/value

This work demonstrates the capabilities of OpenSees for Fire in modelling structural behaviours subjected to non-uniform fire conditions and investigates the damage pattens of flat slabs exposed to localised fires. It is an advancing step towards understanding structural responses to realistic fires.

Details

Journal of Structural Fire Engineering, vol. 14 no. 1
Type: Research Article
ISSN: 2040-2317

Keywords

Access Restricted. View access options
Article
Publication date: 28 February 2019

Ataollah Taghipour Anvari, Mustafa Mahamid, Michael McNallan and Mohammadreza Eslami

The purpose of this paper is to present the effect of damaged fireproofing on structural steel members. This study will show that a minor damage in fireproofing will reduce the…

234

Abstract

Purpose

The purpose of this paper is to present the effect of damaged fireproofing on structural steel members. This study will show that a minor damage in fireproofing will reduce the fire rating of members significantly. Damaged fireproofing happens in structures due to various reasons, and the question is always how effective is this fireproofing? This paper presents the results of one type of fireproofing and presents a parametric study on the size of damage and its effect on fire resistance of structural steel members.

Design/methodology/approach

The study has been performed using numerical methods, thermal and structural finite element analysis. The analysis method has been verified by experimental results.

Findings

Small fire protection damage or loss leads to significant rise of temperature at the damaged parts and causes severe fire resistance reduction of beams. The higher fire protection damage’s extension at the bottom flange of the steel beams does not have any major influence on the rate of reduction of fire resistance of the beams. Steel beams experience greater fire resistance reduction at higher load levels because of the existing of higher stresses and loads within the steel beam section.

Research limitations/implications

The study has been performed using finite element analysis, and it covers a wide range of practical sizes. However, experimental work will be performed by the researchers when funding is granted.

Practical implications

The study provides researchers and practitioners with an estimate on the effect of damaged fireproofing on fire resistance of structural steel beams.

Social implications

Understanding the effect of the effect of damaged fireproofing helps in estimating the fire resistance of structural steel members, which may protect collapses and disasters.

Originality/value

The research is original; extensive literature review has been performed, and this research is original.

Details

Journal of Structural Fire Engineering, vol. 10 no. 1
Type: Research Article
ISSN: 2040-2317

Keywords

Access Restricted. View access options
Article
Publication date: 14 June 2010

Venkatesh Kodur and Monther Dwaikat

The effect of fire induced restraint on the fire response of reinforced concrete (RC) beams is addressed in this paper. A macroscopic finite element model, capable of tracing the…

106

Abstract

The effect of fire induced restraint on the fire response of reinforced concrete (RC) beams is addressed in this paper. A macroscopic finite element model, capable of tracing the behavior of restrained RC beams from pre-fire stage to collapse in fire is used in the analysis. The model is applied to investigate the effect of five parameters; namely, degree of axial restraint, span-to-depth ratio, fire scenario, load level, and failure criteria on the fire response of restrained RC beams. Through the results of the parametric study, it is shown that the five parameters have significant influence on fire resistance of RC beams. It is also shown that, fire induced restraint has negative effect on fire resistance of slender RC beams having high span-to-depth ratio.

Details

Journal of Structural Fire Engineering, vol. 1 no. 2
Type: Research Article
ISSN: 2040-2317

Keywords

Access Restricted. View access options
Article
Publication date: 7 April 2023

Chiara Bedon and Christian Louter

Glass material is largely used for load-bearing components in buildings. For this reason, standardized calculation methods can be used in support of safe structural design in…

54

Abstract

Purpose

Glass material is largely used for load-bearing components in buildings. For this reason, standardized calculation methods can be used in support of safe structural design in common loading and boundary conditions. Differing from earlier literature efforts, the present study elaborates on the load-bearing capacity, failure time and fire endurance of ordinary glass elements under fire exposure and sustained mechanical loads, with evidence of major trends in terms of loading condition and cross-sectional layout. Traditional verification approaches for glass in cold conditions (i.e. stress peak check) and fire endurance of load-bearing members (i.e. deflection and deflection rate limits) are assessed based on parametric numerical simulations.

Design/methodology/approach

The mechanical performance of structural glass elements in fire still represents an open challenge for design and vulnerability assessment. Often, special fire-resisting glass solutions are used for limited practical applications only, and ordinary soda-lime silica glass prevails in design applications for load-bearing members. Moreover, conventional recommendations and testing protocols in use for load-bearing members composed of traditional constructional materials are not already addressed for glass members. This paper elaborates on the fire endurance and failure detection methods for structural glass beams that are subjected to standard ISO time–temperature for fire exposure and in-plane bending mechanical loads. Fire endurance assessment methods are discussed with the support of Finite Element (FE) numerical analyses.

Findings

Based on extended parametric FE analyses, multiple loading, geometrical and thermo-mechanical configurations are taken into account for the analysis of simple glass elements under in-plane bending setup and fire exposure. The comparative results show that – in most of cases – thermal effects due to fire exposure have major effects on the actual load-bearing capacity of these members. Moreover, the conventional stress peak verification approach needs specific elaborations, compared to traditional calculations carried out in cold conditions.

Originality/value

The presented numerical results confirm that the fire endurance analysis of ordinary structural glass elements is a rather complex issue, due to combination of multiple aspects and influencing parameters. Besides, FE simulations can provide useful support for a local and global analysis of major degradation and damage phenomena, and thus support the definition of simple and realistic verification procedures for fire exposed glass members.

Access Restricted. View access options
Article
Publication date: 26 March 2024

Hesam Ketabdari, Amir Saedi Daryan, Nemat Hassani and Mohammad Safi

In this paper, the seismic behavior of the gusset plate moment connection (GPMC) exposed to the post-earthquake fire (PEF) is investigated.

40

Abstract

Purpose

In this paper, the seismic behavior of the gusset plate moment connection (GPMC) exposed to the post-earthquake fire (PEF) is investigated.

Design/methodology/approach

For this purpose, for the sake of verification, first, a numerical model is built using ABAQUS software and then exposed to earthquakes and high temperatures. Afterward, the effects of a series of parameters, such as gusset plate thickness, gap width, steel grade, vertical load value and presence of the stiffeners, are evaluated on the behavior of the connection in the PEF conditions.

Findings

Based on the results obtained from the parametric study, all parameters effectively played a role against the seismic loads, although, when exposed to fire, it was found that the vertical load value and presence of the stiffener revealed a great contribution and the other parameters could not significantly affect the connection performance. Finally, to develop the modeling and further study the performance of the connection, the 4 and 8-story frames are subjected to 11 accelerograms and 3 different fire scenarios. The findings demonstrate that high temperatures impose rotations on the structure, such that the story drifts were changed compared to the post-earthquake drift values.

Originality/value

The obtained results can be used by engineers to design the GPMC for the combined action of earthquake and fire.

Details

Journal of Structural Fire Engineering, vol. 15 no. 4
Type: Research Article
ISSN: 2040-2317

Keywords

Access Restricted. View access options
Article
Publication date: 11 January 2022

Abdelkadir Fellouh, Abdelkader Bougara, Paulo Piloto and Nourredine Benlakehal

Investigate the fire performance of eccentrically loaded concrete partially encased column (PEC), using the advanced calculation method (ANSYS 18.2, 2017) and the simple…

164

Abstract

Purpose

Investigate the fire performance of eccentrically loaded concrete partially encased column (PEC), using the advanced calculation method (ANSYS 18.2, 2017) and the simple calculation method in Annex G of Eurocode 4 (EN 1994-1-2, 2005). This work examines the influence of a range of parameters on fire behaviour of the composite column including: eccentricity loading, slenderness, reinforcement, fire rating and fire scenario. In this study, ISO-834 (ISO834-1, 1999) was used as fire source.

Design/methodology/approach

Currently, different methods of analysis used to assess the thermal behaviour of composite column exposed to fire. Analytical method named simplified calculation methods defined in European standard and numerical simulations named advanced calculation models are treated in this paper.

Findings

The load-bearing capacity of the composite column becomes very weak in the presence of the fire accident and eccentric loading, this recommends to avoid as much as possible eccentric loading during the design of construction building. The reinforcement has a slight influence on the temperature evolution; moreover, the reinforcement has a great contribution on the load capacity, especially in combined compression and bending. When only the two concrete sides are exposed to fire, the partially encased composite column presents a high load-bearing capacity value.

Originality/value

The use of a three-dimensional numerical model (ANSYS) allowed to describe easily the thermal behaviour of PEC columns under eccentric loading with the regard to the analytical method, which is based on three complex steps. In this study, the presence of the load eccentricity has found to have more effect on the load-bearing capacity than the slenderness of the composite column. Introducing a load eccentricity on the top of the column may have the same a reducing effect on the load-bearing capacity as the fire.