1 – 2 of 2Qing Li, Chulin Li, Dongdong Dong, Huimin Han, Guangwu Sun, Xiaona Chen, Hongyan Hu, Wenfeng Hu, Hong Xie and Yanmei Li
This study aims to evaluate how the structure of medical compression stockings, including three compression levels and five cross-sections from the ankle to the thigh part, will…
Abstract
Purpose
This study aims to evaluate how the structure of medical compression stockings, including three compression levels and five cross-sections from the ankle to the thigh part, will be changed after washing in different conditions and further investigate the effect of the washing parameters on the medical compression stockings.
Design/methodology/approach
By washing medical compression stockings in different conditions and measuring the structures (including the density, the girth, the transversal and lengthwise dimension, the weight per unit area and the thickness) of medical compression stockings from the knee to the thigh part.
Findings
It was concluded that the density, the weight per unit and the thickness increase and the girth, the transversal and lengthwise dimension, the weight per unit and the thickness decrease. The change degree of Class one and Class two is greater than Class 3. Moreover, the washing temperature is the most significant factor affecting all the structures of medical compression stockings. Meanwhile, the mechanical actions of the washing machine, like drum speed and washing time, also influence different medical compression stockings structures to different degrees.
Research limitations/implications
The washing parameter not only includes the temperature and washing cycles but also has other factors, such as the drum speed and washing time. In addition, different kinds of factors will be influenced by each other.
Originality/value
This study can provide consumers advices on the washing of medical compression stockings, and attribute to the optimization of materials and structures to maintain its properties for manufacturers.
Details
Keywords
Ahmed Youcef, Rachid Saim and Hakan F. Öztop
The purpose of this paper is to give a comparison between different type of baffles for a better application. Computational analysis of heat transfer and fluid flow through plain…
Abstract
Purpose
The purpose of this paper is to give a comparison between different type of baffles for a better application. Computational analysis of heat transfer and fluid flow through plain, flower and perforated baffles for heat exchanger.
Design/methodology/approach
Numerical simulations for heat exchangers with plain, flower and perforated baffles are carried out with finite volume method. The thermal-hydraulic performance for the three types is presented in the same conditions.
Findings
The perforated baffles generate low shell pressure with high Nusselt number; transverse baffles give the best heat transfer with high pumping power. The overall performance coefficient of these three types of heat exchangers shows that the perforated baffles have a highest and the transverse baffles have the lowest. Analysis of the results show that perforated transverse baffles produce pressure drop lower by 6.68% than transverse baffles and 2.64% lower than flower baffles. The pumping power for perforated transverse baffles lower by 13.3% to the transverse baffles and 4.72% lower than that of flower baffles. The Nusselt number for perforated baffles higher by 4.16% to the flower baffles and 2.77% with transverse baffles. The overall performance factor in the heat exchanger with perforated baffles higher by 5.55% to that with transverse baffles and 3.46% with flower baffles. Recirculation areas are reduced in shell with perforated baffles and velocity distribution becomes more uniform.
Originality/value
Using of perforated baffles in heat exchanger give the best overall performance factor.