Reduction of exceeding the guaranteed service time for external trucks at the DCT Gdańsk container terminal using a six sigma framework
International Journal of Lean Six Sigma
ISSN: 2040-4166
Article publication date: 25 April 2023
Issue publication date: 7 November 2023
Abstract
Purpose
The purpose of this paper is to investigate ways to reduce the average amount of exceeded guaranteed service time for external trucks at Deepwater Container Terminal Gdańsk Sp z o.o. (DCT Gdańsk) via dosing the gate activities, in particular IN-Gate entry process, of trucks carrying import/export/transit containers.
Design/methodology/approach
A Six Sigma methodology with the define, measure, analyze, improve, and Control (DMAIC) methods along with the SIPOC chart, cause and effect diagram, scatterplot, benchmark and brainstorming and finally multi-voting tool are used as analyses tools in this research.
Findings
DCT Gdańsk reorganized and modernized the gate operations. Gate reorganization and modernization include streaming line traffic at the gates, external parking lot optimization, implementation of dedicated supporting software and installation of dedicated CCTV cameras to provide 24 h live view. During gates development, the external truck service times data were collected and analysed. The obtained materials concerned the measurement of the average truck turnaround time before and after the implementation of the improvements.
Originality/value
The proposed approach of reducing the average amount of exceeded guaranteed service time of external trucks at the container terminal is unique and relatively cheap mainly due to organizational changes with some widely available low-cost investments and can be applied on a different scale to other container terminals or to transport and logistics companies.
Keywords
Acknowledgements
Research was partially financed by Polish budget funds for science from Ministerstwo Edukacji i Nauki as a research project 0059/DW/2018/DW/2018/02.
Citation
Moszyk, K. and Deja, M. (2023), "Reduction of exceeding the guaranteed service time for external trucks at the DCT Gdańsk container terminal using a six sigma framework", International Journal of Lean Six Sigma, Vol. 14 No. 7, pp. 1566-1595. https://doi.org/10.1108/IJLSS-05-2022-0100
Publisher
:Emerald Publishing Limited
Copyright © 2023, Emerald Publishing Limited