To read this content please select one of the options below:

Corrosion and cavity wall ties

J.F.A. Moore (Building Research Establishment, Garston, Watford WD2 7JR)

Anti-Corrosion Methods and Materials

ISSN: 0003-5599

Article publication date: 1 February 1982

84

Abstract

Based on laboratory measurements of the thickness of zinc on some 150 wall ties removed from 80 buildings owned by the Property Services Agency and local authorities, typical lives are deduced for galvanised wall ties conforming to the minimum standards of BS 1243:1978. It is concluded that more durable ties are required for new construction but that the majority of existing buildings are sufficiently robust for widespread problems to be unlikely.

Citation

Moore, J.F.A. (1982), "Corrosion and cavity wall ties", Anti-Corrosion Methods and Materials, Vol. 29 No. 2, pp. 8-9. https://doi.org/10.1108/eb007187

Publisher

:

MCB UP Ltd

Copyright © 1982, MCB UP Limited

Related articles