To read this content please select one of the options below:

Predictive model for corrosion hazard of buried metallic structure caused by stray current in the subway

Chengtao Wang (College of Mechatronic Engineering, China University of Mining and Technology, Xuzhou, China)
Wei Li (College of Mechatronic Engineering, China University of Mining and Technology, Xuzhou, China)
Yuqiao Wang (College of Mechatronic Engineering, China University of Mining and Technology, Xuzhou, China)
Xuefeng Yang (College of Mechatronic Engineering, China University of Mining and Technology, Xuzhou, China)
Shaoyi Xu (College of Mechatronic Engineering, China University of Mining and Technology, Xuzhou, China)
Kunpeng Li (Guangzhou Metro Design and Research Institute Co, Guangzhou, China)
Yunyun Zhao (Guangzhou Metro Design and Research Institute Co, Guangzhou, China)

Anti-Corrosion Methods and Materials

ISSN: 0003-5599

Article publication date: 2 August 2019

Issue publication date: 9 August 2019

241

Abstract

Purpose

The purpose of this paper is to predict quantitative level of stray current leaking to the buried metallic structure by establishing convolution neural network (CNN) model.

Design/methodology/approach

First, corrosion experimental system of buried metallic structure is established. The research object of this paper is the polarization potential within 110 min, CNN model is used to predict the quantitative level of stray current leakage using the data from corrosion experimental system further. Finally, results are compared with the method using BP neural network.

Findings

Results show that the CNN model has better predictive effect and shorter prediction time than the BP model, the accuracy of which is 82.5507 per cent, and the prediction time is shortened by more than 10 times.

Originality/value

The established model can be used to forecast the level of stray current leakage in the subway system effectively, which provides a new theoretical basis for evaluating the stray current corrosion hazard of buried metallic structure.

Keywords

Acknowledgements

The authors acknowledge the Project Funded by National Natural Science Foundation of China (NSFC) (51607178), China Postdoctoral Science Foundation (2018T110570), China Postdoctoral Science Foundation (2019M652005) and the Priority Academic Program Development of Jiangsu Higher Education Institutions (PAPD) for the financial support to this research.

Citation

Wang, C., Li, W., Wang, Y., Yang, X., Xu, S., Li, K. and Zhao, Y. (2019), "Predictive model for corrosion hazard of buried metallic structure caused by stray current in the subway", Anti-Corrosion Methods and Materials, Vol. 66 No. 4, pp. 486-495. https://doi.org/10.1108/ACMM-04-2018-1921

Publisher

:

Emerald Publishing Limited

Copyright © 2019, Emerald Publishing Limited