To read this content please select one of the options below:

CFD investigation of temperature distribution, air flow pattern and thermal comfort in natural ventilation of building using solar chimney

Maher Dhahri (Department of Horticultural Systems Engineering and Natural Environment, High Institute of Agronomy of Chott Mariem, Sousse University, Sousse, Tunisia and Department of Physics, Laboratory of Energy and Materials (LabEM), High School of Sciences and Technology of Hammam Sousse, Sousse University, Hammam Sousse, Tunisia)
Hana Aouinet (Higher Private School of Engineering and Applied Techniques (IHE-ESPITA), Sousse, Tunisia)

World Journal of Engineering

ISSN: 1708-5284

Article publication date: 31 January 2020

Issue publication date: 19 February 2020

333

Abstract

Purpose

The purpose of this study is to investigate air flow, temperature distribution and thermal confort in natural ventilation induced by solar chimney for different operating.

Design/methodology/approach

Numerical simulation is performed using a commercial computational fluid dynamics (CFD) package ANSYS CFX software to understand the effects of air temperature, air velocity and solar heat flux on the performance of the solar chimney and thermal comfort. The comfort level was evaluated using the air diffusion performance index (ADPI) according to ASHRAE (55-210). The flow was investigated at inclination angles 45° solar heat flux 550-750 W/m2 and in a solar chimney of 1.4 m length, 0.6 m width and 0.20 m air gab.

Findings

The numerical results from the present simulation were first validated with experimental data, which was used for the thermal comfort indexes calculation. The obtained results of the analysis showed that the used numerical technique could accurately predict air flow and temperature distribution in natural ventilated building using solar chimney; the air temperature, air velocity and solar heat flux have a significant impact on thermal comfort; the temperature of 19°C with velocity of 0.15 m.s−1 gives the best effective draft temperature (EDT) satisfy ASHRAE (55-210) criteria that V = 0.35 m.s−1 and EDT range between −1.7 and 1.1.

Originality/value

In the present paper, air flow, temperature distribution and thermal comfort inside a room equipped with inclined solar chimney were numerically investigated and analyzed. The commercial CFD package (CFX 15) is used. Calculations are carried out in an empty room without any human or mechanical activity and the numerical results are compared with measurement points.