To read this content please select one of the options below:

Tapered plastic optical fiber coated with single wall carbon nanotubes polyethylene oxide composite for measurement of uric acid concentration

Malathy Batumalay (Department of Electrical Engineering, Faculty of Engineering, Photonics Research Centre, University of Malaya, Kuala Lumpur, Malaysia)
F. Ahmad (Department of Electrical Engineering, Faculty of Engineering, University of Malaya, Kuala Lumpur, Malaysia and Electrical Engineering Department, Universiti Teknologi Malaysia, Kuala Lumpur, Malaysia)
Asiah Lokman (Department of Electrical Engineering, Faculty of Engineering, University of Malaya, Kuala Lumpur, Malaysia and Electrical Engineering Department, Universiti Teknologi Malaysia, Kuala Lumpur, Malaysia)
A.A. Jasim (Department of Electrical Engineering, Faculty of Engineering, Photonics Research Centre, University of Malaya, Kuala Lumpur, Malaysia)
Sulaiman Wadi Harun (Department of Electrical Engineering, Faculty of Engineering, Photonics Research Centre, University of Malaya, Kuala Lumpur, Malaysia)
H. Ahmad (Photonics Research Centre, University of Malaya, Kuala Lumpur, Malaysia)

Sensor Review

ISSN: 0260-2288

Article publication date: 14 January 2014

369

Abstract

Purpose

A simple tapered plastic optical fiber (POF) sensor is proposed and demonstrated for measurement of uric acid concentrations in de-ionized water. The paper aims to discuss these issues.

Design/methodology/approach

The sensor operates based on intensity modulation technique as the tapered POF probe which was coated by a single walled carbon nonotubes polyethylene oxide (SWCNT-PEO) composite is immersed into the uric acid solution. The probe was fabricated using an etching method and has a waist diameter of 0.46 mm and tapering length of 10 mm.

Findings

As the concentration varies from 0 to 500 ppm, the output voltage of the sensor increases linearly from 6.13 to 7.35 mV with a sensitivity of 0.0023 mV/% and a linearity of more than 97.20 percent. The SWCNT-PEO composite coating increases the sensitivity of the proposed sensor due to the effective cladding refractive index, which increases with the coating and thus allows more light to be transmitted from the tapered fiber.

Originality/value

This is the first demonstration of the tapered POF sensor for measurement of uric acid concentrations in de-ionized water.

Keywords

Citation

Batumalay, M., Ahmad, F., Lokman, A., Jasim, A.A., Wadi Harun, S. and Ahmad, H. (2014), "Tapered plastic optical fiber coated with single wall carbon nanotubes polyethylene oxide composite for measurement of uric acid concentration", Sensor Review, Vol. 34 No. 1, pp. 75-79. https://doi.org/10.1108/SR-09-2012-699

Publisher

:

Emerald Group Publishing Limited

Copyright © 2014, Emerald Group Publishing Limited

Related articles