To read this content please select one of the options below:

Kinetic study and characterization of a platinum electrode/sensitive membrane for malachite green detection

Ilhem Ghodbane (Department of Process Engineering, Badji Mokhtar University-Annaba, Annaba, Algeria)
Rochdi Kherrrat (Universite Badji Mokhtar Annaba, Annaba, Algeria)
Saida Zougar (Universite Badji Mokhtar Annaba, Annaba, Algeria)
Rim Lamari (Universite Badji Mokhtar Annaba, Annaba, Algeria)
Redouane Haddadji (Swiss Federal Institute of Technology in Lausanne, Lausanne, Switzerland)
Mohamed Saleh Medjram (Universite du 20 aout 1955 de Skikda, Skikda, Algeria)

Sensor Review

ISSN: 0260-2288

Article publication date: 20 March 2018

Issue publication date: 24 May 2018

132

Abstract

Purpose

The purpose of this work is to explore electrical properties of an electrochemical sensor designed for the detection of malachite green (MG) present in an aqueous solution.

Design/methodology/approach

The present sensor consists in the spatial coupling of a polymeric membrane and an ion-sensitive electrode (platinum electrode). The preparation of the polymeric membrane involves the incorporation of an ionophore (D2HPA), a polymer (polyvinylchloride [PVC]) and a plasticizer (dioctyl phthalate [DOP]). Several techniques have been used to characterize this sensor: the cyclic voltammetry, the electrochemical impedance spectroscopy and the optical microscopy. The sensibility, the selectivity and the kinetic study of a modified platinum electrode have been evaluated by cyclic voltammetry.

Findings

The obtained results reveal the possibility of a linear relationship between the current of reduction peaks and MG concentration. A linear response was obtained in a wide-concentration range that stretches from 10−5 to 10−13 mol L−1, with a good correlation coefficient (0.976) and a good detection limit of 5.74 × 10−14 mol L−1 (a signal-to-noise ratio of 3). In addition, the voltammetric response of modified electrode can be enhanced by adding a layer of Nafion membrane. Under this optimal condition, a linear relationship was obtained, with a correlation coefficient of 0.986 and a detection limit of 1.92 × 10−18 mol L−1.

Originality/value

In the present research, a convenient, inexpensive and reproducible method for the detection of MG was developed. The developed sensor is capable of competing against the conventional techniques in terms of speed, stability and economy.

Keywords

Citation

Ghodbane, I., Kherrrat, R., Zougar, S., Lamari, R., Haddadji, R. and Medjram, M.S. (2018), "Kinetic study and characterization of a platinum electrode/sensitive membrane for malachite green detection", Sensor Review, Vol. 38 No. 3, pp. 335-344. https://doi.org/10.1108/SR-06-2017-0099

Publisher

:

Emerald Publishing Limited

Copyright © 2018, Emerald Publishing Limited

Related articles