Wearable medical apparatus to monitor temperature and pulsatile-blood-flow signal on forefoot to predict diabetic foot ulcers
Research Journal of Textile and Apparel
ISSN: 1560-6074
Article publication date: 25 May 2022
Issue publication date: 10 April 2024
Abstract
Purpose
The purpose of this paper is to develop a prototype of a wearable medical device in the form of a bandage with a real-time data monitoring platform, which can be used domestically for diabetic patients to identify the possibility of foot ulceration at the early stage.
Design/methodology/approach
The prototype can measure blood volumetric change and temperature variation in the forefoot area simultaneously. The waveform extracted using a pulsatile-blood-flow signal was used to assess blood perfusion-related information, and hence, predict ischemic ulcers. The temperature difference between ulcerated and the reference was used to predict neuropathic ulcers. The medical device can be used as a bandage during the application wherein the sensory module is placed inside the hollow pocket of the bandage. A platform was developed through a mobile application where doctors can extract real-time information, and hence, determine the possibility of ulceration.
Findings
The height of the peaks in the pulsatile-blood-flow signal measured from the subject with foot ischemic ulcers is significantly less than that of the subject without ischemic ulcers. In the presence of ischemic ulcers, the captured waveform flattens. Therefore, the blood perfusion from arteries to the tissue of the forefoot is considerably low for the subject with ischemic ulcers. According to the temperature difference data measured over 25 consecutive days, the temperature difference of the subject with neuropathic ulcers occasionally exceeded the 4 °F range but mostly had higher values closer to the 4 °F range. However, the temperature difference of the subject who had no complications of neuropathic ulcers did not exceed the 4 °F range, and the majority of the measurements occupy a narrow range from −2°F to 2 °F.
Originality/value
The proposed prototype of wearable medical apparatus can monitor both temperature variation and pulsatile-blood-flow signal on the forefoot simultaneously and thereby predict both ischemic and neuropathic diabetes using a single device. Most importantly, the wearable medical device can be used domestically without clinical assistance with a real-time data monitoring platform to predict the possibility of ulceration and the course of action thereof.
Keywords
Citation
Bulathsinghala, R.L., Wijeyaratne, S.M., Fernando, S., Jayawardana, T.S.S., Senadhipathi Mudiyanselage, V.U.I. and Kankanamalage, S.L.S. (2024), "Wearable medical apparatus to monitor temperature and pulsatile-blood-flow signal on forefoot to predict diabetic foot ulcers", Research Journal of Textile and Apparel, Vol. 28 No. 2, pp. 169-184. https://doi.org/10.1108/RJTA-11-2021-0135