Mechanoreception of pneumatic soft robotic finger without tactile sensor based on dual-position feature

Kai Shi (Department of Fluid Control and Automation, Harbin Institute of Technology, Harbin, China)
Jun Li (Department of Fluid Control and Automation, Harbin Institute of Technology, Harbin, China)
Gang Bao (Department of Fluid Control and Automation, Harbin Institute of Technology, Harbin, China)

Industrial Robot

ISSN: 0143-991X

Article publication date: 11 July 2024

54

Abstract

Purpose

Mechanoreception is crucial for robotic planning and control applications, and for robotic fingers, mechanoreception is generally obtained through tactile sensors. As a new type of robotic finger, the soft finger also requires mechanoreception, like contact force and object stiffness. Unlike rigid fingers, soft fingers have elastic structures, meaning there is a connection between force and deformation of the soft fingers. It allows soft fingers to achieve mechanoreception without using tactile sensors. This study aims to provide a mechanoreception sensing scheme of the soft finger without any tactile sensors.

Design/methodology/approach

This research uses bending sensors to measure the actual bending state under force and calculates the virtual bending state under assumed no-load conditions using pressure sensors and statics model. The difference between the virtual and actual finger states is the finger deformation under load, and its product with the finger stiffness can be used to calculate the contact force. There are distinctions between the virtual and actual finger state change rates in the pressing process. The difference caused by the stiffness of different objects is different, which can be used to identify the object stiffness.

Findings

Contact force perception can achieve a detection accuracy of 0.117 N root mean square error within the range of 0–6 N contact force. The contact object stiffness perception has a detection average deviation of about 15%, and the detection standard deviation is 10% for low-stiffness objects and 20% for high-stiffness objects. It performs better at detecting the stiffness of low-stiffness objects, which is consistent with the sensory ability of human fingers.

Originality/value

This paper proposes a universal mechanoreception method for soft fingers that only uses indispensable bending and pressure sensors without tactile sensors. It helps to reduce the hardware complexity of soft robots. Meanwhile, the soft finger no longer needs to deploy the tactile sensor at the fingertip, which can benefit the optimization design of the fingertip structure without considering the complex sensor installation. On the other hand, this approach is no longer confined to adding components needed. It can fully use the soft robot body’s physical elasticity to convert sensor signals. Essentially, It treats the soft actuators as soft sensors.