An assessment of indoor environmental quality in COVID-19 affected houses: a case study in Banda Aceh, Indonesia
International Journal of Building Pathology and Adaptation
ISSN: 2398-4708
Article publication date: 18 July 2022
Issue publication date: 20 November 2024
Abstract
Purpose
During the COVID-19 pandemic in 2020–2021 in Indonesia, the indoor environmental quality (IEQ) of local houses occupied by infected occupants was adversely affected. This paper aims to appraise the IEQ of the affected Banda Aceh houses with insights into enabling them to be resilient against the negative impacts of the pandemic.
Design/methodology/approach
Quantitative field measurement in the case study of five concrete houses located in urban areas which are affected by IEQ factors: (1) indoor air quality (IAQ), (2) thermal comfort and (3) visual comfort, compared against the Indonesian National standard (SNI). The case study involved measurement of the first two factors over 24 h, while the third factor was measured during sun hours. Considering the limitations of the measuring tools for logging available data in this research, air quality is measured from 8 am to 10 pm.
Findings
Thermal comfort in the affected houses is generally regarded as warm, optimal and cool comfort, indicated by the effective temperatures of between 20.5 and 27.1°C. Frequently closed windows, limited land area and access had caused a lack of air circulation, with air velocity of dominantly 0 m/s in the houses. The illuminance of natural light received in three houses was insufficient – less than 120 lux as compared with the other two. This study found an uptrend of higher air temperature and relative humidity in the affected houses resulting in poorer IAQ; conversely, the higher the air velocity in the houses, the fewer the indoor air pollutants such as formaldehyde (HCHO), total volatile organic compounds (TVOC) and carbon dioxide (CO2).
Originality/value
This study is a pioneer in evaluating IEQ in houses occupied by COVID-19 patients in Indonesia, especially in dwelling cases in Aceh Province. It also encompasses environmental and societal challenges to sustaining resilient buildings in pandemic hit regions.
Keywords
Acknowledgements
This research was supported by Universitas Syiah Kuala (USK) through the “Lektor” research Grant funded in 2021. The authors also thank the students from USK “Faraisha and Rania”, who helped to do the field measurement.
Citation
Sari, L.H., Kayan, B.A. and Zahriah, Z. (2024), "An assessment of indoor environmental quality in COVID-19 affected houses: a case study in Banda Aceh, Indonesia", International Journal of Building Pathology and Adaptation, Vol. 42 No. 5, pp. 932-956. https://doi.org/10.1108/IJBPA-02-2022-0033
Publisher
:Emerald Publishing Limited
Copyright © 2022, Emerald Publishing Limited