To read this content please select one of the options below:

Investigation of a novel hydraulic tunnel composite lining with polyurea coating interlayer

Bingqi Li (China Institute of Water Resources and Hydropower Research, Beijing, China)
Jilei Zhang (China Institute of Water Resources and Hydropower Research, Beijing, China)
Xiaonan Liu (China Institute of Water Resources and Hydropower Research, Beijing, China)
Tianyi Meng (China Institute of Water Resources and Hydropower Research, Beijing, China)

Engineering Computations

ISSN: 0264-4401

Article publication date: 29 July 2024

Issue publication date: 2 August 2024

27

Abstract

Purpose

Multilayer composite liner structures are the primary structural form of hydraulic tunnels. However, the bearing mechanism of multilayer composite liners has not been investigated thoroughly. Many existing design schemes do not properly achieve a balance between structural safety, anti-seepage capacity, and cost effectiveness. Thus, a new composite liner structure type and its theoretical model was proposed.

Design/methodology/approach

A novel hydraulic tunnel composite liner structure with a polyurea spray coating interlayer was proposed in this study. A theoretical model based on the state-space method was developed and verified using FEM models and existing theoretical models. Parametric analysis was conducted based on the theoretical model to investigate the influence of various variables, including interfacial shear stiffness, inner liner thickness, and outer liner elastic modulus.

Findings

It was concluded that the proposed theoretical model can be used successfully to calculate multilayer composite liner structures with high calculation efficiency. The overall deformation stiffness of the composite liner system increased with the interfacial shear stiffness. The sprayed coating interlayer significantly affects the residual force distribution between the outer and inner liners, which can also be affected by the adjustment of the thickness of the outer and inner liners. Thus, attention should be paid to these factors in the rational design of the proposed composite liner system.

Originality/value

With the development of China’s water conservancy projects, complex geological conditions, high surrounding rock stress, high internal and external water pressures, and other unique application scenarios have gradually increased. This places higher requirements on the bearing performance and impermeability of hydraulic tunnel lining structures. On the other hand, conventional hydraulic tunnel lining structures can hardly achieve a satisfactory balance between economy, structural safety, and impermeability. Thus, the proposed structure has the potential to be used in a wide range of applications.

Keywords

Citation

Li, B., Zhang, J., Liu, X. and Meng, T. (2024), "Investigation of a novel hydraulic tunnel composite lining with polyurea coating interlayer", Engineering Computations, Vol. 41 No. 6, pp. 1640-1671. https://doi.org/10.1108/EC-01-2024-0011

Publisher

:

Emerald Publishing Limited

Copyright © 2024, Emerald Publishing Limited

Related articles