Parameters optimization design method for LLC resonant converter based on impedance model
ISSN: 0305-6120
Article publication date: 2 December 2022
Issue publication date: 9 January 2024
Abstract
Purpose
This paper aims to better design the resonant tank parameters for LLC resonant converter. And, it is found that under heavy load, the voltage gain is affected by junction capacitors of the primary side switching and the parasitic parameters of the secondary side diodes converted to the primary side, which will cause the voltage gain decreased when the switching frequency decreased.
Design/methodology/approach
This paper proposes an optimization parameters design method to solve this problem, which was based on impedance model considering the parasitic parameters of switching devices and diodes.
Findings
The effectiveness of the proposed method is verified by impedance Bode plots and experimental results.
Originality/value
From the perspective of impedance modeling, this paper finds the reasons for the insufficient voltage regulation capability of LLC resonant converters under heavy load and finds solutions through analysis.
Keywords
Citation
Yao, X., Han, X., Liao, Y. and Wang, J. (2024), "Parameters optimization design method for LLC resonant converter based on impedance model", Circuit World, Vol. 50 No. 1, pp. 82-89. https://doi.org/10.1108/CW-07-2022-0199
Publisher
:Emerald Publishing Limited
Copyright © 2022, Emerald Publishing Limited