Analysis of linear induction machines with internal fault by MEC
ISSN: 0332-1649
Article publication date: 3 July 2017
Abstract
Purpose
The purpose of this paper is to introduce an asymmetric structure of the magnetic equivalent circuit (MEC) for analysis of the linear induction machine (LIM) with an internal short circuit fault.
Design/methodology/approach
By applying a proper MEC to the LIM, a generalized relation for the inductance matrix of the machine can be directly determined. To evaluate the proposed model, the stator currents and the air-gap flux with the proposed technique are given and compared to the simulation and experimental results in the healthy and fault conditions.
Findings
The LIM is an axial flux machine with a wide range of applications in high-performance drives. Due to a well-tried effect of the first tooth and the last one (the end effect), the performance level of the LIM decreases. Also, the analysis of the linear machines in fault conditions illustrates more complexity compared to the rotary induction machine. However, the MEC is very simple, describing the behavior of the asymmetric electromechanical devices using the magnetic reluctance or the permeance of flux paths.
Originality/value
Using the proposed model, there would be some decrease in the complications of the LIM analysis in the asymmetrical conditions. Moreover, analyzing some of the characteristics of the LIM, such as turn-fault condition, it can be calculated with high accuracy.
Keywords
Citation
Nosrati, A. and Nazarzadeh, J. (2017), "Analysis of linear induction machines with internal fault by MEC", COMPEL - The international journal for computation and mathematics in electrical and electronic engineering, Vol. 36 No. 4, pp. 959-979. https://doi.org/10.1108/COMPEL-08-2016-0360
Publisher
:Emerald Publishing Limited
Copyright © 2017, Emerald Publishing Limited