To read this content please select one of the options below:

Does electrolyzed water have different sanitizing effects than sodium hypochlorite on different vegetable types?

Se-Young Ju (Dankook University, Yongin, Republic of Korea)
Jin-Ju Ko (Dankook University, Cheonan, Republic of Korea)
Hee-Sun Yoon (Dankook University, Cheonan, Republic of Korea)
Su-Jin Seon (Dankook University, Cheonan, Republic of Korea)
Yu-Ri Yoon (Dankook University, Cheonan, Republic of Korea)
Da-In Lee (Dankook University, Cheonan, Republic of Korea)
So-Yeon Kim (Dankook University, Cheonan, Republic of Korea)
Hye-Ja Chang (Dankook University, Cheonan, Republic of Korea)

British Food Journal

ISSN: 0007-070X

Article publication date: 6 February 2017

392

Abstract

Purpose

The purpose of this paper is to examine the efficacy of microbial elimination using different sanitizers in raw vegetables (cherry tomatoes, spring onions, Chinese chives, and chicory) and to analyze the efficacy of Escherichia coli O157:H7 reduction by type of sanitizer and vegetable.

Design/methodology/approach

To assess the sanitizing effects of microbial elimination by variety of vegetable, the samples were grouped into four different washing methods: control (no sanitizer), 100 ppm chlorine, 100 ppm electrolyzed water, and 200 ppm electrolyzed water after prewashing. Subsequently, quantitative microbiological experiments were conducted to assess aerobic mesophilic plate count (APC), coliform, E. coli, and Bacillus cereus, and sensory changes of the sanitized vegetables were tested. Thereafter, measurement of the sanitizing effects on bacterial reduction after inoculation with E. coli O157:H7 was conducted.

Findings

The microbial levels of four types of vegetables ranged from 3.37 to 5.24 log CFU/g for APC, 2.41 to 5.57 log CFU/g for E. coli, 0.25 to 5.40 log CFU/g for coliform, and 0.83 to 5.44 log CFU/g for B. cereus. After three types of sanitizing treatments, microbial reduction effects showed 0.94-1.84 log CFU/g for APC, 0.56-1.00 log CFU/g for E. coli, 0.18-1.26 log CFU/g for coliform, and 0.56-1.23 log CFU/g for B. cereus (p<0.05). In sensory evaluation, there were no significant differences in taste and flavor between with and without sanitizing treatments. Regarding bacterial reduction after inoculation with E. coli O157:H7, the microbial reduction on vegetables was shown to be in the range of 0.27-1.57 log CFU/g with 100 ppm sodium hypochlorite, 0.66-3.07 log CFU/g with 100 ppm electrolyzed water, and 0.79-2.55 log CFU/g with 200 ppm electrolyzed water. Chicory, cherry tomato, and spring onion showed significant reduction levels of E. coli O157:H7 after sanitation (p<0.05).

Originality/value

This study revealed that different sanitization methods are required for different types of vegetables. Electrolyzed water treatment (100 ppm) is a more effective and safe method of washing raw vegetables. Given that the main purpose of sanitizing fresh-cut produce is to maximally reduce microorganism levels, different methods of sanitizing fresh-cut produce with an adequate washing method should be used according to vegetable type.

Keywords

Citation

Ju, S.-Y., Ko, J.-J., Yoon, H.-S., Seon, S.-J., Yoon, Y.-R., Lee, D.-I., Kim, S.-Y. and Chang, H.-J. (2017), "Does electrolyzed water have different sanitizing effects than sodium hypochlorite on different vegetable types?", British Food Journal, Vol. 119 No. 2, pp. 342-356. https://doi.org/10.1108/BFJ-06-2016-0283

Publisher

:

Emerald Publishing Limited

Copyright © 2017, Emerald Publishing Limited

Related articles