To read this content please select one of the options below:

Influence of cryogenic impacting and succeeding annealing on electrochemical corrosion behavior of coarse-grain Cu bulk in sodium chloride solution

Jun Zhu (Research and Development Department, TSP Blue Island Offshore Co. Ltd., Qidong, China)
Wei Luo (State Key Laboratory of Silicon Materials, School of Materials Science and Engineering, Zhejiang University, Hangzhou, China)
Wentao Xv (State Key Laboratory of Silicon Materials, School of Materials Science and Engineering, Zhejiang University, Hangzhou, China)
Shuigen Xv (Hangzhou Oxygen Plant Group Co. Ltd., Hangzhou, China)
XinYang Zhang (State Key Laboratory of Silicon Materials, School of Materials Science and Engineering, Zhejiang University, Hangzhou, China)
Jiefang Zhao (Hangzhou Oxygen Plant Group Co. Ltd., Hangzhou, China)

Anti-Corrosion Methods and Materials

ISSN: 0003-5599

Article publication date: 16 June 2022

Issue publication date: 4 August 2022

57

Abstract

Purpose

This paper aims to study the electrochemical corrosion performance of ultrafine-grained (UFG) Cu bulk in 0.5 M NaCl solution.

Design/methodology/approach

UFG Cu bulk were prepared by impacting at −196°C and following heat treatment. The electrochemical corrosion behaviors of coarse-grained (CG), impacted and subsequently annealed at 190°C Cu bulks were studied.

Findings

All the bulks displayed typical active-passive-transpassive behaviors (dual passive films without stable passive regions). The resistance to corrosion of impacted Cu bulk was notably superior to that of CG Cu bulk, and subsequently annealing further improved its corrosion resistance.

Social implications

Except for mechanical properties, corrosion performance has been considered to be one of the most important aspects in bulk UFG metallic materials research for the prospective engineering applications.

Originality/value

Cryogenic impacting could effectively reduce grain size of CG Cu bulk to UFG scale and induce high density dislocation. Subsequent annealing resulted in a further decrease of grain size even to nanoscale, as well as nanometer twins. The grain refinement, high density dislocation and annealing twins effectively enhance the passivation capability, resulting in an increase in the corrosion resistance.

Keywords

Acknowledgements

This work was financially supported by Zhejiang Provincial Natural Science Foundation of China under Grant No. LY17E010004.

Citation

Zhu, J., Luo, W., Xv, W., Xv, S., Zhang, X. and Zhao, J. (2022), "Influence of cryogenic impacting and succeeding annealing on electrochemical corrosion behavior of coarse-grain Cu bulk in sodium chloride solution", Anti-Corrosion Methods and Materials, Vol. 69 No. 5, pp. 499-505. https://doi.org/10.1108/ACMM-05-2021-2481

Publisher

:

Emerald Publishing Limited

Copyright © 2022, Emerald Publishing Limited

Related articles