Automatic press-fit assembly of small precision interference fitting parts: armature of electro-hydraulic servo valve
ISSN: 0144-5154
Article publication date: 2 September 2019
Issue publication date: 18 October 2019
Abstract
Purpose
The purpose of this paper is to design an automatic press-fit instrument to realize precision assembly and connection quality assessment of a small interference fitting parts, armature.
Design/methodology/approach
In this paper, an automatic press-fit instrument was developed for the technical problems of reliable clamping and positioning of the armature, automatic measurement and adjustment of the attitude and evaluation of the connection quality. To compensate for the installation error of the equipment, corresponding calibration method was proposed for each module of the instrument. Assembly strategies of axial displacement and perpendicularity were also proposed to ensure the assembly accuracy. A theoretical model was built to calculate the resistant force generated by the non-contact regions and then combined with the thick-walled cylinder theory to predict the press-fit curve.
Findings
The calibration method and assembly strategy proposed in this paper enable the press-fit instrument to achieve good alignment and assembly accuracy. A reasonable range of press-fit curve obtained from theoretical model can achieve the connection quality assessment.
Practical implications
This instrument has been used in an armature assembly project. The practical results show that this instrument can assemble the armature components with complex structures automatically, accurately, in high-efficiency and in high quality.
Originality/value
This paper provides a technical method to improve the assembly quality of small precision interference fitting parts and provides certain methodological guidelines for precision peg-in-hole assembly.
Keywords
Acknowledgements
This research work was supported by National Science and Technology Major Project of China (Grant No. 2013ZX0400109) and Major Project of Basic Scientific Research of Chinese Ministry (Grant No. JCYK2016 205A003).
Citation
Wang, X., Lou, Z., Wang, X., Wang, Y., Hao, X. and Wang, Z. (2019), "Automatic press-fit assembly of small precision interference fitting parts: armature of electro-hydraulic servo valve", Assembly Automation, Vol. 39 No. 5, pp. 986-998. https://doi.org/10.1108/AA-08-2018-112
Publisher
:Emerald Publishing Limited