To read this content please select one of the options below:

Influence of the discretization error on the reconstruction accuracy in electrical capacitance tomography

Daniel Watzenig (Institute of Electrical Measurement and Measurement Signal Processing, Graz, Austria)
Gerald Steiner (Institute of Electrical Measurement and Measurement Signal Processing, Graz, Austria)
Anton Fuchs (Institute of Electrical Measurement and Measurement Signal Processing, Graz, Austria)
Hubert Zangl (Institute of Electrical Measurement and Measurement Signal Processing, Graz, Austria)
Bernhard Brandstätter (Institute of Electrical Measurement and Measurement Signal Processing, Graz, Austria)

Abstract

Purpose

The investigation of the influence of the modeling error on the solution of the inverse problem given uncertain measured data in electrical capacitance tomography (ECT).

Design/methodology/approach

The solution of the nonlinear inverse problem in ECT and hence, the obtainable accuracy of the reconstruction result, highly depends on the numerical modeling of the forward map and on the required regularization. The inherent discretization error propagates through the forward map, the solution of the inverse problem, the subsequent calculation of process parameters and properties and may lead to a substantial estimation error. Within this work different finite element meshes are compared in terms of obtainable reconstruction accuracy. In order to characterize the reconstruction results, two error measures are introduced, a relative integral error and the relative error in material fraction. In addition, the influence of the measurement noise given different meshes is investigated from the statistical point of view using repeated measurements.

Findings

The modeling error, the degree of regularization, and measurement uncertainties are the determining and limiting factors for the obtainable reconstruction accuracy of electrical tomography systems. The impact of these key influence factors on the calculation of process properties given both synthetic as well as measured data is quantified. Practical implications – The obtained results show that especially for measured data, the variability in calculated parameters strongly depends on the efforts put on the forward modeling, i.e. on an appropriate finite element mesh size. Hence, an investigation of the modeling error is highly recommended when real‐world tomography problems have to be solved.

Originality/value

The results presented in this work clearly show how the modeling error as well as inherent measurement uncertainties influence the solution of the inverse problem and the posterior calculation of certain parameters like void fraction in process tomography.

Keywords

Citation

Watzenig, D., Steiner, G., Fuchs, A., Zangl, H. and Brandstätter, B. (2007), "Influence of the discretization error on the reconstruction accuracy in electrical capacitance tomography", COMPEL - The international journal for computation and mathematics in electrical and electronic engineering, Vol. 26 No. 3, pp. 661-676. https://doi.org/10.1108/03321640710751136