The current distribution within multi strand windings is investigated for transient current and voltage supplies. The difference in losses between transient and sinusoidal waveforms is elaborated. Therefore, a wide range of frequencies as well as different kinds of transient waveforms has been investigated. The definition of the skin depth is no longer sufficient. A new parameter is required for transients, which is related to time. This parameter will be defined and called “skin time”. A numerical method is developed based upon a finite element transient calculation. The method is applied to the winding as well as to the core. A comparison with measurements verifies the approach described.

Keywords

Citation

Drubel, O. (2003), "Current distribution within multi strand windings for electrical machines with frequency converter supply", COMPEL - The international journal for computation and mathematics in electrical and electronic engineering, Vol. 22 No. 4, pp. 1166-1181. https://doi.org/10.1108/03321640310483084

Publisher

:

MCB UP Ltd

Copyright © 2003, MCB UP Limited

Related articles