To read this content please select one of the options below:

Optimization of TiO2 concentration effect for a chemical humidity sensing mechanism

Souhil Kouda (Laboratoire d'Electronique Avancée, Département d'Electronique, Université de Batna, Batna, Algerie)
Zohir Dibi (Laboratoire d'Electronique Avancée, Département d'Electronique, Université de Batna, Batna, Algerie)
Fayçal Meddour (Laboratoire d'Electronique Avancée, Département d'Electronique, Université de Batna, Batna, Algerie)
Samir Barra (Laboratoire d'Electronique Avancée, Département d'Electronique, Université de Batna, Batna, Algerie)
Abdelghani Dendouga (Laboratoire d'Electronique Avancée, Département d'Electronique, Université de Batna, Batna, Algerie)

Sensor Review

ISSN: 0260-2288

Article publication date: 25 January 2011

348

Abstract

Purpose

The purpose of this paper is to propose a new approach to optimize the TiO2 concentration on a resistive‐type humidity sensing mechanism (RHSM) based on artificial neural network.

Design/methodology/approach

First is the modeling of the sensing mechanism. Using neuronal networks and Matlab environment to accurately express the output of the sensing mechanism, this model thus takes into account the parameter, non‐linearity, hysteresis, temperature and frequency; furthermore, the TiO2 concentration effect on the humidity sensing properties in the model is investigated. In a second step, the Matlab environment is used to create a database for an ideal model for the sensing mechanism, where the response of this ideal model is linear for any above parameters value.

Findings

An analytical model for the sensing mechanism “SM” and the ideal model “IM” has been created. The bias matrix and the weights matrix were used to establish the SM model and the IM on performance simulation program with integrated circuit emphasis simulator, where the output of the first is identical to the RHSM output and the output of the last is the ideal response.

Originality/value

The paper proposes an electrical circuit used to optimize the TiO2 concentration of a resistive humidity sensing mechanism.

Keywords

Citation

Kouda, S., Dibi, Z., Meddour, F., Barra, S. and Dendouga, A. (2011), "Optimization of TiO2 concentration effect for a chemical humidity sensing mechanism", Sensor Review, Vol. 31 No. 1, pp. 18-25. https://doi.org/10.1108/02602281111099044

Publisher

:

Emerald Group Publishing Limited

Copyright © 2011, Emerald Group Publishing Limited

Related articles